Direct Programming Manual
Edge
Smart Keypads and Card Readers
10
If you need help, please email
or call
(972) 474-6390
.
Four tones:
Mode 4 enabled.
Five tones:
Mode 5 enabled.
Enter 0 and listen for good tone.
Enter # key to exit Programming Mode.
Mode 1
When this mode is active, the selected relay will be triggered when the state of Event Input 1
changes from normally open (N/O) to normally closed (N/C).
1251
$
4
$
9
$
1
$
X
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 4 and listen for good tone.
Enter secondary sub mode 9 and listen for status tones:
Good tone:
Event Input 1 is disabled (Mode 0).
One tone:
Mode 1 enabled.
Two tones:
Mode 2 enabled.
Three tones: Mode 3 enabled.
Four tones:
Mode 4 enabled.
Five tones:
Mode 5 enabled.
Enter 1 for Mode 1 and listen for good tone.
Enter 1 (for Relay A) or 2 (for Relay B) and listen for good tone.
Enter # key to exit Programming Mode.
Mode 2
When this mode is active, a log entry of the event input state will be made when the state of
Event Input 1 changes from normally open (N/O) to normally closed (N/C).
1251
$
4
$
9
$
2
$
#
Enter Master Code (default 1251) and listen for good tone.
Enter sub mode 4 and listen for good tone.
Enter secondary sub mode 9 and listen for status tones:
Good tone:
Event Input 1 is disabled (Mode 0).
One tone:
Mode 1 enabled.
Two tones:
Mode 2 enabled.
Three tones: Mode 3 enabled.
Four tones:
Mode 4 enabled.
Five tones:
Mode 5 enabled.
Enter 2 for Mode 2 and listen for good tone.
Enter # key to exit Programming Mode.