Step 12
Push the grease into the galley until the expelled grease at
the opposite end of the propeller end cap is clean grease.
Step 13
Repeat steps 11 and 12 for each thruster.
Step 14
Reinstall the black plastic screws into each thruster
propeller end cap being careful not to over tighten.
Step 15
Wipe away any excess grease from each thruster.
Reassemble
Reverse steps 1-9 in this procedure as well as steps 1-15 of
4.1.1
Cleaning LBV.
4.2
Every 500 hours
After operating the LBV for 500 hours it is recommended that the seals be replaced
throughout the LBV including the thrusters. Contact SeaBotix, Inc. or your nearest
authorized repair distributor.
4.3
Long term
There is little need for long term maintenance as long as the LBV is taken care of and
the 500 hour maintenance is performed. There may be a need to replace the view port
if it is scratched excessively. Replacement of some fasteners may be required as they
may corrode with time.
4.4
Repairs
Should the LBV require service or repair, contact SeaBotix, Inc. or an authorized repair
facility for information. If you choose to repair the LBV on your own there are a variety
of procedure(s) manuals available at
www.seabotix.com
.