4. Rotate the vertical thruster knob (on the left side) to ensure that the vertical
thruster operates correctly.
5. Push and hold the VERT key while selecting 1-0 on the keypad to adjust the
gain control. The value will change on the Video Overlay.
6. Push the HORZ key while selecting 1-0 on the keypad to adjust the horizontal
thruster gain control. The value will appear on the Video Overlay.
NOTE:
Do not run the thrusters for more than a few seconds at a time
with the LBV out of the water. Operating the thrusters for more than a
few seconds may cause damage to the motors and/or the shaft seals.
1.4.3.2
Camera(s)
1. Push TILT + and TILT – to rotate the camera chassis.
2. Push FOCUS + and FOCUS – to focus the camera.
3. Push CAMERA select button to switch to the optional second camera (if
fitted).
a. Test FOCUS + and FOCUS – on the second camera if fitted.
NOTE:
The FOCUS function will not operate on a rear facing camera.
4. Push the LIGHT key to turn on the internal light.
5. Push + and – to vary the light intensity
a. Repeat with the second camera if fitted.
NOTE:
Do not leave the light on for more than a few seconds when the
LBV is out of the water. Leaving the light on may cause damage to the
view port or the lighting control circuits.
1.4.3.3
Video Overlay
1. Check that the time is set correctly (page 25, section 2.2.1.8).
2. Calibrate that date is set correctly (page 25, section 2.2.1.9).
3. Calibrate the heading (page 24, section 2.2.1.3)
4. Check that the desired depth measurement is set correctly (page 24, section
2.2.1.5).
5. Check that the desired temperature is set correctly (page 25, section 2.2.1.7).
6. Input desired User Text (page 25, section 2.2.2.0).
1.4.3.4
Accessories
1. If fitted with accessories such as a grabber (page 25 section 2.3.1) and test
the and the keys to ensure that the grabber closes and opens.