0.35 SW1 push-button functions – ALL led signalling mode
DG0
DG1
DG2
DG3
DG4
DG5
DG6
0 3 5
0 0
DG3
[0.35.0]
SW1
PUSH
-
BUTTON
FUNCTION
0
With SW1 is possible to reset alarms that require manual reset
1
With SW1 is
not
possible to reset alarms that require manual reset
DG4
[0.35.1]
ALL
LED
SIGNALLING
MODE
0
The ALL led indicates that at least one alarm has been added to the error log
1
The ALL led indicates the alarm code of any alarm that is causing out of service. For any digit of
the alarm code, a corresponding number of flashes are emitted (ten flashes are emitted for “0”)
0.36 Shaft sensors state
DG0
DG1
DG2
DG3
DG4
DG5
DG6
0 3 6
DG3 : state of virtual input
DG4 : state of virtual input
DG5 : state of virtual input
DG6 : state of virtual input
DG3 … DG6 may be 0 or 1, with the same meaning already seen for the parameter 0.34.
Setting the cursor on DG3 … DG6, a note will be output from the buzzer on the STK1R board with a
frequency which depends on the state of the IS and ID sensors, as shown in the following table.
IS
ID
Note
0
0
-
0
1
DO
7
1
1
MI
7
1
0
SOL
7
© 2019