SEA SYSTEMS
INSTALLATION AND USE
STK1R control panels (Setronik1 Restyling)
STK1R-EN-62-0-A
rev0
24/01/2019
0.09 Car movement commands
DG0
DG1
DG2
DG3
DG4
DG5
DG6
0 0 9
DG3
[0.09.0] [0.09.1]
C
AR
MOVEMENT
COMMANDS
0
No command. The lift works normally
1
Random calls at all floors, with door opening and closing:
- set the cursor on DG4 to start the command
- set the cursor on DG3 and select 0 to stop the command
To set the time between one call and the next, use timer 4.65
The command is effective only with STK2-PM programmer connected and switched on
2
Random calls at all floors except for the lowest floor, with door opening and closing:
- set the cursor on DG4 to start the command
- set the cursor on DG3 and select 0 to stop the command
To set the time between one call and the next, use timer 4.65
The command is effective only with STK2-PM programmer connected and switched on
3
Upward / downward movement command at low speed.
- Set the cursor on DG4
- Press and hold down the ˅ push-button to go down, ˄ to go up
4
Upward / downward movement command at low speed for UCM test (the safety circuit CS4 is not
turned off)
- Set the cursor on DG4
- Press and hold down the ˅ push-button to go down, ˄ to go up.
(see STK1R-A3-P instructions for UCM test)
5
Call to the lowest or the highest floor.
- set the cursor on DG4
- Press ˅ for the lowest floor, ˄ for the highest one.
6
Call to the next floor above or below the current car position
- Set the cursor on DG4
- Press ˅ for the next floor below the car, ˄ for the next floor above.
DG4
[0.00.1]
C
AR
MOVEMENT
STATE
0
Car is motionless (at landings or not)
1
Car is moving upward
2
Car is moving downward
DG5
[0.09.2]
C
ALLS
DISABLING
0
No new call is disabled (lift work normally)
1
New external (floor) calls are disabled
2
New internal (car) calls are disabled
3
New external and internal calls are disabled
© 2019
Sea Systems
Page 29 of 99