SEA SYSTEMS
INSTALLATION AND USE
STK1R control panels (Setronik1 Restyling)
STK1R-EN-62-0-A
rev0
24/01/2019
9.xx Floors table: heights and stop distances (with Encoder)
Shows the heights of each landing and the ascending and descending stop distances that were acquired
using parameter 9.00. It is possible to modify the heights of each landing.
DG0
DG1
DG2
DG3
DG4
DG5
DG6
9 x x _
DG3456=
[9.
XX
.0]
Floor height in mm, first part: thousands
(0000
9999)
DG0
DG1
DG2
DG3
DG4
DG5
DG6
9 x x 0 _
DG456=
[9.
XX
.0]
Floor height in mm, second part: units
(000
999)
DG0
DG1
DG2
DG3
DG4
DG5
DG6
9 x x 0
_
DG456=
[9.
XX
.1]
Stop distance above the floor (downward)
in mm (000
255)
DG0
DG1
DG2
DG3
DG4
DG5
DG6
9 x x 0
_
DG456=
[9.
XX
.2]
Stop distance below the floor (upward) in
mm (000
255)
XX = Floor number (from 01 to 24)
The stop distances are measured automatically during the shaft learning procedure (see
parameters
) and
should never be changed manually
.
© 2019
Sea Systems
Page 76 of 99