SEA SYSTEMS
INSTALLATION AND USE
STK1R control panels (Setronik1 Restyling)
STK1R-EN-62-0-A
rev0
24/01/2019
0.37 State of some virtual inputs dealing with the doors
DG0
DG1
DG2
DG3
DG4
DG5
DG6
0 3 7
DG3 … DG6 show the state of the main virtual inputs used to manage the doors, in the following way.
DG3 flashing:
•
DG3 : state of virtual input VI.06 (opening limit switch of door A / “door A is moving” signal)
•
DG4 : state of virtual input VI.30 (closing limit switch of door A)
•
DG5 : state of virtual input VI.46 (obstruction while closing door A)
•
DG6 : state of virtual input VI.23 (door A photocell)
DG4 flashing:
•
DG3 : state of virtual input VI.07 (opening limit switch of door B / “door B is moving” signal)
•
DG4 : state of virtual input VI.31 (closing limit switch of door B)
•
DG5 : state of virtual input VI.47 (obstruction while closing door B)
•
DG6 : state of virtual input VI.24 (door B photocell)
DG5 flashing:
•
DG3 : state of virtual input VI.54 (opening limit switch of door C/ “door C is moving” signal)
•
DG4 : state of virtual input VI.78 (closing limit switch of door C)
•
DG5 : state of virtual input VI.48 (obstruction while closing door C)
•
DG6 : state of virtual input VI.51 (door C photocell)
DG6 flashing:
•
DG3 : state of virtual input VI.43 (door A opening push-button)
•
DG4 : state of virtual input VI.29 (door B opening push-button)
•
DG5 : state of virtual input VI.45 (door C opening push-button)
•
DG6 : state of virtual input VI.42 (door opening unique push-button)
In all cases DG3 … DG6 may be 0 or 1, with the same meaning already seen for the parameter 0.34.