10 Hostmode
U
1 Here is the PTC-IIex – The PTC-IIex switches on the connect text and the text will be
“Here is the PTC-IIex ”.
U
1 – asks for the connect text
U
0 – switches off the connect text
If
U
is set to 2, the sequences
//B
<CR> and
//Q
<CR> are accepted additionally. The
two sequences are recognized if they occur at the beginning of a line and are closed
directly with <CR> or <Return>.
//B
initiates the sysop-bell (duration about 14 seconds). After receiving
//Q
the PTC
initiates a disconnect.
The sysop-bell is set using the
BEll
command of the
cmd:-
menu (refer to chapter
6.11
,
page
42
)
10.4.18
V
Gives a longer version string.
10.4.19
W
Default setting: 100
Parameter: X 1... 30,000, slot time in milliseconds.
Defines the slot time for the transmitter control.
The PTC-IIex can transmit at particular times only.
W
(Slottime) defines the period
between these times.
10.4.20
Y
Default setting: 4
Parameter: X 0... 31, number of users.
Limits the number of channels available for remote users.
Y
5 limits the number of connects from outside to five, so if the PTC is presently
connected to by 5 stations, and a further station attempts to connect, this connect request
will be refused.
The
Y
command allows any incoming PR-connect to be transferred to the PTC-IIex PR-
mailbox, but only if
Y
has to be set to 0. This will allow for example, that on exiting the
terminal program, (e.g. automatic de-initialization with
Y
0 in
GP
) the PTC-IIex can be
brought to a condition where a connect using the
normal MYCALL
(i.e. without the -8)
will be transferred to the mailbox. This is useful, as many potential users would use the
normal MYCALL
to connect to the PTC-IIex. If the terminal is
off-line
, and the
configuration is correct, (
Y
0) then all calls, irrespective of if they are the
normal
MYCALL
, the
MYALIAS
, or the
BBS-MYCALL
, will be transferred to the PTC-mailbox.
The
Y
-command has no effect on self initiated connects, the number of channels is not
limited for the user. It is thus possible, with
Y
= 0 to initiate up to 31 PR-connects in
parallel!
137
Содержание PTC-IIex
Страница 14: ...List of Figures and Tables XII...
Страница 30: ...3 Installation 16...
Страница 108: ...7 Audio 94...
Страница 126: ...8 FAX 112...
Страница 173: ...12 SYStest 159...
Страница 183: ...14 Circuit Description 169...
Страница 195: ...15 Basics 181...
Страница 201: ...B Technical Data 187...
Страница 202: ...C Layout Appendix C 19 Layout B 1 Motherboard Figure B 1 Motherboard 188...
Страница 203: ...C Layout 189...
Страница 215: ...Index 202...