Controller Information
Machine Indicator Lights
•
Power
•
Status
•
Water
•
Clean
Code Display
Main codes
- automatically displayed
F
. . . . . . . Freeze Cycle
F
flashes . . Freeze Cycle is Pending
H
. . . . . . . Harvest Cycle
H
flashes . . Manual Harvest
b
. . . . . . . Bin is Full
C
. . . . . . . Clean Cycle
L
. . . . . . . Board Locked
d
. . . . . . . Test Mode
O
. . . . . . . Off
E
. . . . . . . Self Test Failed
1
flashes . . Max Freeze - Retrying
1
. . . . . . . Max Freeze Time Shut Down
2
flashes . . Max Harvest - Retrying
2
. . . . . . . Max Harvest Time Shut Down
3
. . . . . . . Slow Water Fill
4
. . . . . . . High Discharge Temp
5
. . . . . . . Sump Temp Sensor Failure
7
. . . . . . . Discharge Temp Sensor Failure
8
flashes . . Short Freeze - Retrying
8
. . . . . . . Short Freeze - Thin ice
Setting Codes
- requires push button sequence
Water Purge Settings
A, 1, 2, 3, 4, 5
De-Scale notification
- see table to the right
November 2008 Page 22
Change De-Scale Notification Interval -
This feature is accessible only from
standby (Status Light Off).
1. Press and hold harvest button for 3
seconds.
This starts the Time to Clean
Adjustment Mode and displays the
current time to clean setting.
2. Press the clean button repeatedly to
cycle through the 4 settings:
Prior
Effective 11/6/08
3 months
1 year
4 months
0 or disabled
5 months
4 months
6 months (default)
6 months (default)
3. Push Off to confirm the selection.
Содержание C0522SR-1
Страница 96: ...Wiring Diagram C0522R C0530R C0630R C0830R C1030R Single Phase after 9 09 September 2009 Page 96 ...
Страница 98: ...Wiring Diagram C0522R C0530R C0630R C0830R C1030R Three Phase after 9 09 September 2009 Page 98 ...
Страница 126: ...Wiring Diagram C0630R 6 C0830R 6 C1030R 6 September 2009 ...
Страница 127: ...Wiring Diagram C0830R 63 C1030R 63 September 2009 ...