Compressor
1
Remove front panel.
2
Remove sound shield
3
If the machine was in operation, push and release the Harvest button to shut it down.
Wait until the harvest cycle has ended so the evaporator has no ice on it.
4
Open the replacement compressor box. Check the compressor nameplate, be SURE that
the replacement compressor is the correct one for the unit.
5
Disconnect electrical power.
6
Recover refrigerant.
7
Remove compressor terminal cover and disconnect electrical leads.
8
Remove all the mounting bolts.
9
Open both discharge and suction access valves
10
Connect nitrogen to discharge access valve.
11
Open nitrogen valve.
12
Unsweat the suction, discharge and process tubes.
13
Unsweat the drier from the liquid line. Remove it.
14
Shut the nitrogen valve.
15
Remove the compressor from the ice machine. Note: Some models may require the
control box to be moved slightly to allow compressor replacement.
16
Immediately place new compressor in ice machine.