Electrical
The machine is not supplied with a power cord, one must either be field installed or the
machine hard-wired.
The dataplate on the back of the cabinet details the power requirements, including voltage,
phase, minimum circuit ampacity and maximum fuse size. HACR type circuit breakers may be
used in place of fuses. Extension cords are not permitted. Use of a licensed electrician is
recommended.
The ice maker is designed to operate on its own electrical circuit and must be individually
fused. Voltage variation must not exceed the limits listed earlier.
The remote condenser is designed to be powered from the ice machine. A separate knockout
hole has been provided in the ice maker electrical junction box.
Electrical connections are made inside the junction box in the back panel of the ice machine.
Remove the junction box cover and route the power cord through the access hole and properly
attach the power supply wires to the leads in the junction box.
Attach the remote condenser fan motor wires to the wires in the junction box tagged “fan motor
leads”.
Install field supplied strain reliefs per code. Attach a ground wire to the ground connection in
the junction box.
Check voltage when complete.
Return the junction box cover to its original position and secure with the original screws.
Follow all applicable local, state and national codes.
September 2006 Page 19
General Installation - Remote
Содержание C0522SR-1
Страница 96: ...Wiring Diagram C0522R C0530R C0630R C0830R C1030R Single Phase after 9 09 September 2009 Page 96 ...
Страница 98: ...Wiring Diagram C0522R C0530R C0630R C0830R C1030R Three Phase after 9 09 September 2009 Page 98 ...
Страница 126: ...Wiring Diagram C0630R 6 C0830R 6 C1030R 6 September 2009 ...
Страница 127: ...Wiring Diagram C0830R 63 C1030R 63 September 2009 ...