11-44
Testing and Troubleshooting
Date Code 20010731
SEL-352-1, -2 Instruction Manual
Self-Test Failure: –15 V
1. Power
supply
–15 V output out-of-tolerance. See
STATUS
command.
2. A/D converter failure.
Self-Test Failure: Offset
1. Offset
drift.
2. A/D converter drift.
3. Loose ribbon cable between transformers and main board.
Self-Test Failure: ROM
1. Memory failure. Contact the factory.
Self-Test Failure: RAM
1. Failure of static RAM IC. Contact the factory.
Self-Test Failure: CR_RAM
1. If an R_S or saving settings process was interrupted by loss of power or CTRL-X, issue the
R_S
command again. Settings will return to factory defaults.
2. If cause of the CR_RAM is unknown, contact the factory.
Self-Test Failure: A/D Converter
1. A/D converter failure.
2. RAM error not detected by RAM test.
Self-Test Failure: IO_BRD
1. I/O board has been changed. Execute the
INITIO
command.
2. Ribbon cable disconnected between I/O board and main board. Reconnect and execute
INITIO
command.
3. Interface Board Failure.
Self-Test Failure: CR_RAM, EEPROM, and IO_BRD
1. Self-test detected setting location movement due to flash firmware upgrade. Execute
R_S
command.
2. Main board failure, contact the factory.
Alarm Contacts Closed
1. Power is off.
2. Blown
fuse.
3. Power supply failure.
4. Main board or interface board failure.
5. Other self-test failure.
Содержание SEL-352-1
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 30: ......
Страница 68: ......
Страница 186: ......
Страница 292: ......
Страница 300: ...9 8 Front Panel Interface Date Code 20010731 SEL 352 1 2 Instruction Manual Figure 9 3 Front Panel Operation Map ...
Страница 302: ......
Страница 368: ......
Страница 370: ......
Страница 374: ......
Страница 380: ......
Страница 382: ......
Страница 384: ......
Страница 386: ......
Страница 396: ......
Страница 404: ......
Страница 422: ......
Страница 442: ......