A three-level password scheme protects settings and circuit breaker control. The SEL-352 Relay
monitors password execution and closes the ALARM contact output to indicate possible
unauthorized access. The relay requires no special communications software. Access the relay
with a dumb terminal, printing terminal, or computer with serial port and terminal emulation
software.
M
ODEL
O
PTIONS
SEL-352-1 Relay
The SEL-352-1 Relay has provided sophisticated and reliable service for many years. It
continues to satisfy the needs of most of our customers. However, we recommend using the
SEL-352-2 Relay for new designs because of the additional features it provides.
SEL-352-2 Relay
The SEL-352-2 Relay provides the following additional features:
Overcurrent elements for detecting RMS overcurrent conditions on a per-pole or three-
phase basis (50R, 50RA, 50RB, and 50RC).
Percent Wear function for estimating the amount of breaker contact wear per pole.
BREAKER W
command for preloading the number of operations, total current, total
energy, and percent wear fields in the operation summary on a per-pole basis.
Optional Distributed Network Protocol (DNP) 3.00 Level 2 Slave communications
protocol.
Conventional Terminal Blocks
This model includes hardware that supports three current inputs, six voltage inputs, six
optoisolated inputs, seven programmable output contacts, one alarm contact, three EIA-232 ports,
one EIA-485 port, and IRIG-B time code. It uses terminal blocks that support #6 ring terminals.
This robust package meets or exceeds numerous industry standard type tests.
This relay is available in a 3.50" (2U), 5.25" (3U), or 7.00" (4U) rack-mount package or 4.9",
6.65", or 8.40" panel-mount package. Additional optoisolated inputs and programmable output
contacts are available with the larger packages.
Plug-In Connectors (Connectorized
®
)
This model includes hardware that supports all of the features of the conventional terminal blocks
model. It differs in that it uses plug-in connectors instead of terminal blocks. In addition, it
provides
Quick connect/release hardware for rear-panel terminals.
Level-sensitive optoisolated inputs.
This robust package meets or exceeds numerous industry standard type tests. It is available in a
5.25" (3U) rack-mount package or a 4.9" panel-mount package.
Содержание SEL-352-1
Страница 8: ......
Страница 10: ......
Страница 12: ......
Страница 30: ......
Страница 68: ......
Страница 186: ......
Страница 292: ......
Страница 300: ...9 8 Front Panel Interface Date Code 20010731 SEL 352 1 2 Instruction Manual Figure 9 3 Front Panel Operation Map ...
Страница 302: ......
Страница 368: ......
Страница 370: ......
Страница 374: ......
Страница 380: ......
Страница 382: ......
Страница 384: ......
Страница 386: ......
Страница 396: ......
Страница 404: ......
Страница 422: ......
Страница 442: ......