MAINTENANCE
30.30.01.00127/03
www.schmalz.com
EN | 41
Service table
9.6
Interval
Daily
Weekly
Monthly
Every
six
months
Annual
check
Check safety features:
- Gauge OK?
- Does warning device emit signal at correct low/excess
pressure values?
X
X
Electrical
Vacuum Generation: Service gate valve and
filter of pump as described in the operating instructions
See pump operating instructions
Vacuum filter cleaned?
X
X
Is the electrical installation OK? Are cable screw unions
secure?
X
Are the vacuum hoses in good condition (not brittle,
not kinked, no worn sections and no leaks)?
X
X
Are all connections (hose clamps, etc.) secure?
X
Are the type plate and maximum load plate still attached
to the device?
X
Are the operating instructions still available and are
workers familiar with them?
X
Check all load-bearing parts (e.g. suspension) for
deformation, wear or other damage
.
X
Clean suction plates. Check for cracks,
evenness of suction lip, etc. and replace if necessary
X
X
Has the test label been updated?
X
General condition of the device
X
Leak test
X
X
Oil the bowden cable
X
Cleaning
9.7
Use cleaning solvents to clean the lifting device
(not petroleum ether or corrosive liquids; the use of
petroleum ether or corrosive liquids could cause leaks in the supply hose or lift tube). The suction
plates can be cleaned using soap and warm water; do not use cleaning solvents on the suction
sealing lips!