![Schmalz VacuMaster Window Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/schmalz/vacumaster-window/vacumaster-window_operating-instructions-manual_1212906024.webp)
INSTALLATION
30.30.01.00127/03
www.schmalz.com
EN | 24
Electrical connection
5.4
WARNING
Risk of injury from falling parts
If a load bearing device is installed on the crane with an EMERGENCY STOP,
then if the load falls, the EMERGENCY STOP is incorrectly connected.
This can result in serious injury.
► The electrical connection must be downstream from the crane mains
connection switch and upstream from the chain hoist's EMERGENCY STOP.
The vacuum of the lifting device must not be deactivated when the
EMERGENCY STOP is activated!
DANGER
Electric shock resulting from incorrectly connected components
This can result in death or serious injury from electric shock and fire.
►
All work on electrical equipment must be carried out by qualified electrical
specialists only
►
When working on electrical components of the lifting device, it must be
completely disconnected from the power supply using the upstream
disconnecting switch or maintenance switch.
►
Some components are still live after the lifting device is switched off with the
main switch.
►
Suitable fire extinguishing equipment must be on hand!
Mains supply pin assignment
Mains connection via flat cable chain hoist VacuMaster
Plug
Cable
1
Brown (1)
2
Black (2)
3
Blue or gray (3)
PE
Green/yellow
Electrical connection of VacuMaster Window/Window Comfort without chain hoist
Cable
Contact/fuse K10
Brown (1)
L1
Black (2)
L2
Blue or gray (3)
L3
Green/yellow
PE
Note:
On complete systems (lifting device with chain hoist), the plug is pre-installed and simply needs to be
plugged in.
1
2
3