INSTALLATION
30.30.01.00127/03
www.schmalz.com
EN | 25
Checking the rotational direction of the motor
5.4.1
A clockwise rotation field must be present as the drive limit switch will otherwise be disabled and the
drive or the base body will be damaged.
Equipment for measuring the rotation field (21.05.05.00082) can be ordered from J.Schmalz.
Check the direction of rotation of the motor as follows:
Switch on the pump.
Watch the motor’s fan blade. It must turn in the direction shown
by the arrow on the motor housing.
The device is delivered with a clockwise rotation field.
If the direction of rotation is incorrect, switch the unit off immediately and reverse the connection in
the supply line.
Check the direction of rotation once again.
This work may only be carried out by a qualified electrical specialist.
Damage resulting from operation with the incorrect rotational direction is not covered by the warranty.
Test
5.5
After installation is completed, the system must be tested for leaks (see “Maintenance” section).
Installation of the lifting device is complete following 3-4 successful test runs
using a workpiece. The checks required in Europe before initial use in
accordance with EN 13155 are covered by a type test.