MAINTENANCE
30.30.01.00127/03
www.schmalz.com
EN | 38
9 Maintenance
General notes
9.1
Please read section 1.6 (Requirements & instructions for installation,
maintenance and operating staff) before starting maintenance.
WARNING
Risk of injury due to system maintenance by untrained personnel
This can result in serious injury.
► The system must only be maintained by trained personnel who have read and
understood the operating instructions.
WARNING
Risk of injury from worn, unmaintained parts
Worn and unmaintained parts can cause damage, resulting in failure of the
lifting device and potentially causing severe injury.
► Observe the operating, maintenance and servicing requirements specified in
these operating instructions.
Vacuum pump
9.2
See enclosed pump operating instructions (Appendix).
Suction Plates/Sealing Lips
9.3
Clean stuck objects and dirt such as adhesive, glue, chips, dust, etc. from sealing lips at least once a
week. Use soapy water for cleaning.
Replace damaged or worn suction plates immediately (cracks, holes, corrugation).
Always replace suction plates completely.
Tip: Heating the screw union of the suction plate makes it easier to loosen.
Seal the suction plate connection again when screwing on.