30 | EN
www.schmalz.com
30.30.01.01648/06
Plug FMHD
Pin
Litz wire color
Function (PNP)
1
Brown
Not used
2
White
“Blow off” signal input
or ventilation cylinder
(= depositing workpieces)
3
Blue
Ground
4
Black
“Suction” signal input
(= controlling the separating cylinder)
Adapter set SBX
When using an FMHD with an adapter set, the pin assignments for the Harding plug correspond to
those of the SBX. It is therefore not necessary to adapt the system control unit to the FMHD.
Plug for the adapter set SBX
with ventilation cylinder
Pin
Function (PNP)
1
“Suction” signal input
(= controlling the separating cylinder)
2
“Blow off” signal input
(= depositing workpieces)
3
Ground
4
Not used
5
Ground
6
Not used
Plug for the adapter set SBX
with ejector SBPL
Pin
Function (PNP)
1
“Suction” signal input
(= controlling the separating cylinder)
2
“Vent” signal input
(= depositing workpieces)
3
Ejector signal input
(= switching on the vacuum generator)
4
Not used
5
Ground (PIN 1+2)
6
Ground (PIN 3)
ATTENTION
Incorrectly connected screw union
Malfunction
► The multi-pole plug’s screw union must be sealed securely and correctly during
installation of the customer’s cable
.