Fault
Possible cause
Solution
Pneumatic cylinder is
not working
Cylinder is defective
Repair cylinder or replace if necessary
Operating pressure is too low
Set the compressed air supply to 6 bar;
check the supply lines (is the hose bent
or disconnected?)
Inspect the solenoid valve
Dirt; defective, control
Solenoid valve is not
working
Electrical control is not working
Check the connections and replace
valve if necessary
Solenoid valve is defective
Repair or replace the solenoid valve
Sealing plate wears
out
very quickly
The vacuum area gripper is angled or
makes a grinding noise
when applied
to the workpiece to be lifted
Set it down vertically on the workpiece
Material is not optimal
Contact our sales department
for advice
Workpieces are
no longer deposited
Spring in cylinder is broken,
the cylinder no longer retracts
Replace cylinder or spring
Blow off pulse or ventilation time
too short.
Extend the time and check whether the
function
is performed.
Recommendation
We recommend always performing tests with original sample workpieces. We would
be happy to help you with testing.