IO-Link Data Dictionary
SCPSi series
21.10.01.00065/02
29.08.2014
J. Schmalz GmbH
Aacher Straße 29, D 72293 Glatten
Tel.: +49(0)7443/2403-0
Fax: +49(0)7443/2403-259
[email protected]
Remark
Counter value cc1 of when the data was recorded
Bytes 20…29
Bytes 90…99
Remark
Entry 3
Entry 10 (oldest)
Buffer of 10 entries (newest to oldest) with encoding as in ISDU 133
Primary supply voltage US too high
Manual mode active
System pressure outside of operating range
Implemented IO-Link Events
0x1000
0x5100
0x5110
0x8C01
0x1800
0x1801
0x1802
Event type
Vacuum calibration OK
Vacuum calibration failed
System pressure fault
Notification
Notification
Warning
Simulation active
General malfunction
General power supply fault
Primary supply voltage over-run
Error
Error
Warning
Warning
Event code
Event name
Remark
Internal error e.g. E01 / E02
Primary supply voltage US too low
Data Format of Single Entry (ISDU 134)
Data Format of EPC Data Buffer (ISDU 133)
Bytes 0…9
Bytes 10…19
…
Bytes 2…3
Bytes 4…5
Entry 1 (newest)
Entry 2
…
Bytes 0…1
Evacuation time t1 (MSB first)
Leakage rate (MSB first)
Bytes 6…9
Counter cc1 (MSB first)
Free-flow vacuum (MSB first)
EPC Data Buffer - Details
J. Schmalz GmbH
11 of 11
SCPSi Data Dictionary
Содержание 10.02.02.05235
Страница 1: ...Compact Ejector SCPSi UHV HD Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01484 00 01 21 ...
Страница 16: ...Technical Data 16 72 EN US 30 30 01 01484 00 01 21 4 7 Pneumatic Circuit Plans SCPSi NO SCPSi NC ...
Страница 72: ... J Schmalz GmbH EN US 30 30 01 01484 00 01 21 Subject to technical changes without notice ...