![Schmalz 10.02.02.05235 Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/schmalz/10-02-02-05235/10-02-02-05235_operating-instructions-manual_1212848031.webp)
General Description of Functions
EN-US · 30.30.01.01484 · 00 · 01/21
31 / 72
7.19 Resetting to Factory Settings
This function restores the ejector configuration of the initial setup and the settings of the active produc-
tion setup profile to the factory settings.
WARNING
By activating/deactivating the product, output signals lead to an action in the pro-
duction process!
Personal injury
4
Avoid possible danger zone.
4
Remain vigilant.
The function is executed using the
rE5
menu item in the configuration menu or via IO-Link:
1. Press the
button for more than 3 seconds.
ð
When the menu is locked, enter the valid PIN.
2. Use the
or
button to select the
rE5
menu item.
3. Confirm using the
button.
ð
YE5
appears on the display.
4. Press the
for more than 3 seconds.
ð
The ejector is reset to the factory settings.
ð
The display flashes for a number of seconds and then returns to display mode.
The function for resetting factory settings does not affect the following elements:
•
The counter readings
•
The zero-point adjustment of the sensor
•
The IO-Link parameter “Application Specific Tag”
•
The production setup profiles, which are currently deactivated
The factory settings for the ejector are listed in the Technical Data section.
7.20 Counters
The ejector has two internal counters, [
cc1
] and [
cc2
], which cannot be erased:
Counter 1 increases with each valid pulse at the “suction” signal input, meaning that it counts all the suc-
tion cycles during the ejector’s service life. Counter 2 increases each time the “suction” valve is switched
on. As a result, the average switching frequency of the air saving function can be determined using the
difference between counters 1 and 2.
Designation
Display parameter
Description
Counter 1
[
cc1
]
Counter for suction cycles (“suc-
tion” signal input)
Counter 2
[
cc2
]
Counter for the “suction valve”
switching frequency
Displaying a Counter on the Operating Panel of the Ejector: