Installation
42 / 72
EN-US · 30.30.01.01484 · 00 · 01/21
The vacuum circuit is connected to the vacuum connection.
The installation process is described and explained in detail below.
9.3 Pneumatic Connection
CAUTION
Compressed air or vacuum in direct contact with the eye
Severe eye injury
4
Wear eye protection
4
Do not look into compressed air openings
4
Do not look into the silencer air stream
4
Do not look into vacuum openings, e.g. suction cups
CAUTION
Noise pollution due to incorrect installation of the pressure and vacuum connec-
tions
Hearing damage
4
Correct installation.
4
Wear ear protectors.
9.3.1 Connecting the Compressed Air and Vacuum
WARNING
Activating the compressed air causes the ejector module to be forced out of the
hole.
Serious personal injury
4
Before activating the compressed air supply, make sure that the ejector module is fixed
in place by the holder cap.
4
Wear eye protection
The G1/8" thread compressed air connection is marked with the number 1 on the ejector.
4
Connect the compressed air hose. The max. tightening torque is 3 Nm.
The G1/8" vacuum connection is marked with the number 2 on the ejector.
4
Connect the vacuum hose. The max. tightening torque is 3 Nm.
9.3.2 Instructions for the Pneumatic Connection
Use only screw unions with cylindrical G-threads for the compressed air and vacuum connection!
To ensure problem-free operation and a long service life for the product, only use adequately maintained
compressed air and take the following requirements into account:
•
Use of air or neutral gas in accordance with EN 983, filtered 5 μm, oiled or unoiled.
•
Dirt particles or foreign bodies in the product connections, hoses or pipelines can lead to partial or
complete malfunction.