Technical Data
14 / 72
EN-US · 30.30.01.01484 · 00 · 01/21
Parameter
Symbol
Limit values
Unit
Comment
Current of signal input (PNP)
I
IH
—
5
—
mA
—
Current of signal input (NPN)
I
IL
—
-5
—
mA
—
Reaction time of signal inputs
t
I
—
3
—
ms
—
Reaction time of signal out-
puts
t
O
1
—
200
ms
Adjustable
1) The power supply must correspond to the regulations in accordance with EN60204 (protected extra-low
voltage). The signal inputs and outputs are all protected against reverse polarity.
2) Plus the output currents
3) The signal output is protected against short circuits. However, the signal output is not protected
against overloading. Constant load currents > 0.15 A may lead to impermissible heating and therefore the
destruction of the ejector.
4) Mean value
4.4 Factory Settings
Code
Parameter
Value of the factory setting
X-1
Limit value H1
750 mbar
h-1
Hysteresis value h1
150 mbar
X-2
Limit value H2
550 mbar
h-2
Hysteresis value h2
10 mbar
XP1
Limit value H1
4.0 bar
hp1
Hysteresis value hP1
0.2 bar
tbL
Blow off time
0.2 s
ctr
Control
Activated =
on
dc5
Continuous suction
Deactivated =
off
t-1
Evacuation time
2 s
-L-
Leakage value
250 mbar/s
bLo
Blow off function
Externally controlled blow off =
-E-
uni
Vacuum unit
Vacuum unit in mbar =
-bA
tYP
Signal Type
PNP switching =
PnP
dLY
Switch-off delay
10 ms
dPY
Display rotation
Standard =
5td
Eco
ECO mode
Deactivated =
oFF
Pin
PIN
User-defined
000
o-2
Signal Output
“Normally open” contact = no
The production setup profiles P-1 to P-3 are factory-set to have the exact same data set as the default
data set P-0.