General Description of Functions
EN-US · 30.30.01.01484 · 00 · 01/21
27 / 72
Description
Explanation
The blow off signal overrides the suction signal, even if the specified
blow off time is very long.
The length of the blow off time [
tbL
] is set in the main menu. This menu item is suppressed in operating
mode [
-E-
].
The number displayed indicates the blow off time in seconds. Blow off times from 0.10 seconds to
9.99 seconds can be set.
7.7 Changing the Blow-Off Flow Rate on the Ejector
Do not overwind the stop on the valve screw. A minimum flow rate of approx. 15 % is always
necessary for technical reasons. The blow-off volume flow can be set between 15 % and
100 %.
There is a valve screw below the vacuum connection that can be used to adjust the blow-off flow rate.
The valve screw is equipped with a stop on both sides.
Valve screw
+
-
1. Turn the valve screw clockwise to reduce the flow rate.
2. Turn the valve screw counterclockwise to increase the flow rate.
7.8 Monitoring the Supply Voltages
The ejector is not a voltage meter! However, the measured values and the system responses
derived from them provide a helpful diagnostics tool for condition monitoring.
The ejector measures the supply voltages U
S
. The measured value can be read from the parameter data.
If the voltages are outside the valid range (min. 19.2 V and max. 26.4 V), the following status messages
change:
•
Device status
•
Condition monitoring parameter
•
An IO-Link event is generated
There is no guarantee that the ejector will operate as intended below a supply voltage of 19.2 V:
•
The reaction to signal inputs is disabled.
•
The “Part Present” check output retains its normal functionality.
•
The current supply voltage can still be viewed using the
button.
Содержание 10.02.02.05235
Страница 1: ...Compact Ejector SCPSi UHV HD Operating Instructions WWW SCHMALZ COM EN US 30 30 01 01484 00 01 21 ...
Страница 16: ...Technical Data 16 72 EN US 30 30 01 01484 00 01 21 4 7 Pneumatic Circuit Plans SCPSi NO SCPSi NC ...