Operating and Menu Concept
18 / 72
EN-US · 30.30.01.01484 · 00 · 01/21
The following table shows an overview of the display codes in the main menu:
Display code
Parameter
Explanation
x-1
Vacuum limit value H1
Value at which the control function deactivates
(only if
ctr
=
on
and
oN5
are active)
h-1
Hysteresis value h-1
Hysteresis value for the control function
x-2
Vacuum limit value H2
“Part Present” check switching value
h-2
Hysteresis value h-2
“Part Present” check hysteresis value
tbL
Blow off time
Only activated for
E-t
or
l-t
CAL
Calibration
Calibrate the vacuum sensor
The factory settings for the parameters are listed in the Technical Data section.
5.3 Configuration Menu
An extended configuration menu is available for applications with special requirements.
1. Open the configuration menu by pressing the
button for more than 3 seconds.
ð
During activation, [
-C-
] appears.
2. The parameters are set in accordance with the description in the Main Menu section.
The following table shows an overview of the display codes in the configuration menu:
Display
code
Parameter
Possible settings
Explanation
ctr
Air saving func-
tion
on
oFF
on5
Control active
Control inactive
Valve protection function active (max. permissi-
ble leakage is monitored)
dC5
Deactivate auto.
control shutoff
on
oFF
Suppresses the automatic valve protection func-
tion when set to
YE5
.
Cannot be activated when
Ctr
=
off
.
t-1
Max. permissi-
ble evacuation
time
Configurable be-
tween 0.01 and
9.99 s in 0.01 incre-
ments
off
Permissible evacuation time; evaluation in IO-
Link only
No monitoring
-L-
Max. permissi-
ble leakage
Values from 0 to
999 mbar/s can be
configured in
1 mbar/s increments
Menu item only displayed when
ctr
=
On5
Unit: millibar per second
This value is used for onS and CM warnings. The
adjustable leakage value can be used to judge
the quality of the suction process. Evaluation in
IO-Link only.
bLo
Blow off func-
tion
-E-
1-t
E-t
Externally controlled
Internally controlled (triggered internally, time
can be set)
Externally controlled (triggered externally, time
can be set)
o-2
Signal output 2
no
nc
Configure output 2, “Part Present” check
for normally open
for normally closed
tYP
Signal Type
Define signal type for inputs and outputs