General Description of Functions
24 / 72
EN-US · 30.30.01.01484 · 00 · 01/21
•
Externally time-controlled blow off
The current process state is indicated by the LED status indicators.
During blow off, [
-FF
] is shown on the display.
7.3 Operating Modes
The ejector can be operated in four operating modes:
•
Direct connection to inputs and outputs (standard I/O = SIO)
•
Connection via the communication line (IO-Link)
•
“Manual mode,” operation using the ejector buttons
•
Setup mode
By default, the ejector always runs in SIO mode, but it can be switched in and out of IO-Link mode by an
IO-Link master at any time.
If the ejector is connected to the supply voltage, it is in automatic mode and ready for operation. This is
the normal operating mode, in which the ejector is operated by the system controller. A differentiation is
made between SIO mode and IO-Link mode.
The ejector is always parameterized in automatic mode.
7.3.1 Automatic Operation
Once the ejector is connected to the power supply, it is ready for operation and enters automatic opera-
tion mode. This is the normal operating mode, in which the ejector is operated by the system controller.
The operating mode may be changed from automatic to manual mode using the buttons.
The ejector is always parameterized in automatic mode.
7.3.2 Manual Operating Mode
WARNING
Through an external signal, manual operation is exited, external signals are evalu-
ated and system parts move.
Personal injury or damage to property due to collisions
4
Ensure that the danger zone of the system is clear of people during operation.
4
Wear the required personal protective equipment (PPE) when working in the danger
zone.
WARNING
Falling objects due to incorrect operation in manual mode
Risk of injury
4
Higher level of attention
4
Ensure that there are no persons within the danger zones of the machine/system
In manual mode, a higher level of attention is advisable because incorrect operation may cause gripped
parts to fall, resulting in injuries.
In manual mode, the “suction” and “blow off” ejector functions can be controlled independently of the
higher-level controller using the buttons on the operating panel. In this operating mode, the “H1” and
“H2” LEDs both flash. Because the valve protection function is deactivated in manual mode, this function
can be used to locate and rectify leaks in the vacuum circuit.