OPERATING INSTRUCTIONS
1
4
CG700 rondo
Version: 27202 -
D
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
4.9
Pump Kit Installation
4.10
Connection to the pool
fig. 19
R
Pipework
S
Hexagon screws
V
Adaptor
Mount the pump free of all tension with
the hexagon screws M8 (S) on the base
frame.
Warning!
1. Do not use any vibration dampers
between the pump and the base
frame.
2. If the pipework (R) to the pump is
longer than 6 m then the nominal
width must be increased.
- Suction side from DN 65 to a
min. of DN 80
- Pressure side from DN 50 to a
min. of DN 65.
3. Then always mount the adaptors (V)
on the pump body.
fig. 20
14
Return connection DN 50
17
Suction connection DN 65
20
Housing
Stick the adaptors (14+17) onto the pipe
connections on the housing (20).
Alternatively, by using pipework, stick to
the pump-side end of the pipework.
Warning!
Always be sure to lay the pipework using
bends and not angles to keep the pipe
resistance to a minimum.
8226