Fault Assistance
The functional faults listed in the table are the most frequent causes of defects. If the
corrective measures described are not successful, then the specialist that is called in
individual cases will have to investigate the cause of the fault.
fig. 34: Attaching the massage set
fig. 35: Detaching the massage set
D
Nozzle
F
Hose coupling
V
Sliding sleeve
Warning!
In accordance with UVV (Accident Prevention Regulations) all repairs and
intervention to the unit must be carried out exclusively by qualified persons
otherwise damage (accidents) could result to the user / operator.
Functional fault
Possible cause
Remedy
1. Pump runs very loudly and lacks
performance
Motor rotating in the wrong direction Re-pole the motor in the terminal box
and reverse the direction
Motor blower brushes against the
blower cover
Fasten the blower cover properly
2. Pump starts up heavily and slowly A current phase is missing
Check supplies and fuses