OPERATING INSTRUCTIONS
5
CG700 rondo
Version: 27202 -
D
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
•
The operator must ensure that
- the operator’s manual is always available for users to read,
- instructions in the operator’s manual are being observed,
- the counter-current system is immediately stopped if abnormal electrical voltages,
temperatures, noises, vibrations, leakages or other faults should arise.
2.2
Symbols
In these operating instructions the following symbols are used to draw your special
attention to dangers:
Notices attached directly to the counter-current system , e.g. the arrow indicating the
direction of rotation, must always be observed and maintained in a clearly legible condition.
3
Unit Description / General Technical Data
•
The
fluvo
counter-current system CG700 rondo complies with VDE (Association of
German Engineers) regulations.
•
The electric motor and the water conducting plastic pump are electrically separated.
•
The electric motor complies with protection class IP 55.
•
The entire counter-current system complies with protection class I.
The counter-current system is delivered as 3 assemblies:
1. Pump kit
2. Assembly kit
3. Installation kit
3.1
Technical Data
*
WS = AC
= Alternating current
For more details of safety instructions please see the
operator´s manual
WK
(2722
0
).
Warning! Risk of injury! / Warning! Risk of damage!
This symbol warns you of dangers through mechanical effects and also warns
of handling that could damage the product.
Warning! Mortal danger!
This sign warns you of the danger from electric shocks.
System type:
CG700 1.5
CG700 1.5 WS*
CG700 1.9
CG700 1.9 WS*
CG700 3.0
Capacity
1.5 kW
1.5 kW
1.9 kW
1.9 kW
3 kW
Voltage [V]
400 V Y /
230 V
∆
230 V ~
400 V Y /
230 V
∆
230 V ~
400 V Y /
230 V
∆
Frequency
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
Current
2,8
6 A
9.5 A
3
.6 A
11.
5
A
5,7
5 A
Speed
2840 rpm
2790 rpm
2850 rpm
2820 rpm
2810 rpm
Delivery capacity
42 m³/h
42 m³/h
48 m³/h
48 m³/h
60 m³/h
Delivery pressure
1.2 bar
1.2 bar
1.4 bar
1.4 bar
1.9 bar
Max. speed 2 m from the nozzle
1.15 m/sec.
1.15 m/sec.
1.3 m/sec.
1.3 m/sec.
1.6 m/sec.
Max. water temperature
50 °C
50 °C
50 °C
50 °C
50 °C
Expected sound pressure level
65 + 2 dB (A)
65 + 2 dB (A)
67 + 2 dB (A)
67 + 2 dB (A)
70 + 2 dB (A)
Weight
26
kg
26
kg 2
7
kg 2
7
kg
39
kg