SCHEMPP-HIRTH FLUGZEUGBAU GmbH, KIRCHHEIM/TECK
Ventus-3M „Performance“
FLIGHT MANUAL
March 2019
Revision –
7.3.37
I. Power plant operating unit MCU3 BG
(cont.)
B) Functional description (cont.)
7.1 Error Messages – Tripped fuse of an electrical circuit (FUSE):
Number
FEHLER_SCHALTER_AUSGEFAHREN (50)
Display
Extend sw. malfunc.
Description
Case 1:
When extending the power plant, the extension limit switch is not detected
even after the longest extension period to be assumed.
Case 2:
When the power plant is extended, the spindle drive fuse triggers, which
indicates a mechanical stop of the spindle. drive
In both cases, the extension limit switch is subsequently assumed to be defective. The
extended position can therefore no longer be detected automatically.
Text
Extend end switch not detected. Engine position unknown.
Short text
Extend sw. malfunc.
Number
FEHLER_SCHALTER_EINGEFAHREN (51)
Display
Retract sw. malfunc.
Description
Retract limit switch defective, see FEHLER_SCHALTER_AUSGEFAHREN
Text
Retract end switch not detected. Engine position unknown.
Short text
Retract sw. malfunc.
Number
FEHLER_MAIN_FUSE (52)
Display
Main fuse trig.
Description
No voltage at the power supply input, probably because the external main fuse for the
power plant (Master-switch power plant) has tripped. The fuse must be reset by the
pilot. This error cannot occur in the current hardware version because the SG has no
redundant power supply.
Text
Main fuse triggered. Reset main fuse!
Short text
Main fuse trig.
Number
FEHLER_SPINDLE_FUSE (53)
Display
Spindle fuse trig.
Description
No voltage at spindle drive supply input, probably because the external spindle fuse
has tripped. The fuse must be reset by the pilot. This message is not repeated after
confirmation, and is automatically cleared when the spindle drive power supply is
restored.
Text
Spindel fuse triggered. Reset spindle fuse!
Short text
Spindle fuse trig.
Содержание Ventus-3M Performance
Страница 126: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL March 2019 Revision 5 3 3 2 ...
Страница 204: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL März 2019 Revision 7 9 2 ...
Страница 205: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL March 2019 Revision 7 9 3 ...
Страница 206: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL March 2019 Revision 7 9 4 ...
Страница 210: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL March 2019 Revision 7 11 3 ...
Страница 211: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL March 2019 Revision 7 11 4 ...
Страница 214: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL March 2019 Revision 7 12 3 ...
Страница 215: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL March 2019 Revision 7 12 4 ...
Страница 216: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL March 2019 Revision 7 12 5 ...
Страница 217: ...SCHEMPP HIRTH FLUGZEUGBAU GmbH KIRCHHEIM TECK Ventus 3M Performance FLIGHT MANUAL March 2019 Revision 7 12 6 ...