System
PASCA_TOUCHIT_EN
V02 | 07.2013
96
19) M6 motor water pump
Actuation of the water pump motor.
ON:
The water pump is switched on.
OFF:
The water pump is switched off.
On/off
-
20) heater coffee water (*)
Actuation of the coffee boiler heating.
ON:
The coffee boiler heating is switched
on.
OFF:
The coffee boiler heating is switched
off.
On/off
(*) The marked parame-
ters are automatically swit-
ched off by the machine
control to protect the com-
ponents.
21) heater hot water (*)
Actuation of the hot water boiler heating.
ON:
The hot water boiler heating is
switched on.
OFF:
The hot water boiler heating is
switched off.
On/off
(*) The marked parame-
ters are automatically swit-
ched off by the machine
control to protect the com-
ponents.
22) heater steam (*)
Actuation of the steam boiler heating.
ON:
The steam boiler heating is switched
on.
OFF:
The steam boiler heating is switched
off.
On/off
(*) The marked parame-
ters are automatically swit-
ched off by the machine
control to protect the com-
ponents.
23)
Heating
6000 W
(*)
Actuation of the special boiler heating
6000 W. (second heating element)
ON:
The second boiler heating 6000 W is
switched on.
OFF:
The second boiler heating 6000 W is
switched off.
On/off
(*) The marked parame-
ters are automatically swit-
ched off by the machine
control to protect the com-
ponents.
Only with the appropriate
machine equipment and
activated system parame-
ter.
24) Ext. heating element 1 (*)
"Central Cleaning" machine communication
between two machines regarding enabling of
cleaning.
ON:
Cleaning is enabled in the second
machine.
OFF:
No communication between the ma-
chines.
On/off
Only if two machines are in
use.
Parameters: Output test
Display text
Description
Setting range
Notes