PASCA_TOUCHIT_EN
V02 | 07.2013
69
Configuration
External alarm display
15) Fill milk hose
Sets the filling time of the milk hose.
Fills the milk hose with fresh milk after rin-
sing.
Advantages:
This removes residual water from the milk
hose. The milk dosing remains constant.
0.0-19.9 sec
The standard setting is
0 min.
Milk is not filled if set to "0".
"Milk pump", "Center milk"
or "Twin Milk" must be
selected in the selection
list of the "7 Fresh milk sy-
stem" system parameter.
Setting with "CS" milk system
1 sec
Setting with "UC" milk system
Depends on the
distance bet-
ween the coo-
ling unit and the
machine.
Parameters: Date / Time / Alarm
Display text
Description
Setting range
Notes
Parameters: Alarm output
Display text
Description
Setting range
Notes
Fig. Connection "J4-8" of the external
alarm display
The alarms are signalled using an external
customer-specific alarm system.
This alarm system can signal visually with a
lamp or acoustically with a horn.
If a parameter is switched on in the "Alarm
output" menu, alarms are transmitted to the
connected display device via terminal "J4-8".
The "Alarm output" function makes it possib-
le for users to detect alarms from a distance
when the machine is used in "Self" mode.
-
The alarm output is found
at connection J8, pins 7 &
8, see Fig. "External alarm
display".
If an alarm output is active,
30 V CC are applied at ter-
minal J4-8.
A cable 069715 is needed
to connect the output to an
external 24 V CC Potter &
Brumfield relay (063770).
The "19 Outlet change-
over" system parameter
must be deactivated.