5
Table of Contents
Page
1. Introduction ........................................................................................................................................................... 2
2. Safety precautions ................................................................................................................................................. 3
3. General specifications ........................................................................................................................................... 7
3.1. Packing list ..................................................................................................................................................... 7
3.2. Features .......................................................................................................................................................... 7
3.3. Heating specifications..................................................................................................................................... 7
3.4. Weight ............................................................................................................................................................ 7
3.5. Electrical......................................................................................................................................................... 7
3.6. Fuel................................................................................................................................................................. 7
3.7. Installation (for qualified installer only)......................................................................................................... 7
3.8. Installation warnings ...................................................................................................................................... 8
3.9. Dimensions ..................................................................................................................................................... 9
3.10. Securing the insert / ZC fireplace to the construction. ............................................................................... 10
3.11. Additional items required ........................................................................................................................... 12
3.12. High altitude ............................................................................................................................................... 12
3.13. Gas line installation .................................................................................................................................... 14
3.14. Gas inlet pressure ....................................................................................................................................... 14
4. Installation as insert............................................................................................................................................. 15
4.1. Insert placement requirements...................................................................................................................... 15
4.2. Flex vent manifold assembly........................................................................................................................ 16
4.3. Vent damper adjustment............................................................................................................................... 19
4.4. Approved venting configurations for vertical terminations.......................................................................... 20
4.5. Flex vent installation .................................................................................................................................... 21
5. Installation as ZC-fireplace ................................................................................................................................. 22
5.1. options .......................................................................................................................................................... 22
5.2. Placement requirements for your ZC-fireplace ............................................................................................ 22
5.3. Installation overview .................................................................................................................................... 23
5.4. Installation hints ........................................................................................................................................... 24
5.5. ZC-fireplace clearances ................................................................................................................................ 24
5.6. Mobile home requirements........................................................................................................................... 25
5.7. Floor protection requirements ...................................................................................................................... 25
5.8. Direct vent manifold assembly ..................................................................................................................... 26
5.9. Vent requirements ........................................................................................................................................ 29
5.10. Vent damper adjustment............................................................................................................................. 29
5.11. Approved venting configurations for vertical terminations with two 90° elbows...................................... 30
5.12. Approved venting configurations with a horizontal termination and one 90° elbow................................. 31
5.13. Approved venting configurations for vertical terminations........................................................................ 33
5.14. Vent termination clearances ....................................................................................................................... 36
6. Finalizing the installation .................................................................................................................................... 37
6.1. Outer door assembly..................................................................................................................................... 38
6.2. Removal of glass panels ............................................................................................................................... 42
6.3. Firebrick and baffle plate removal................................................................................................................ 43
7. Operation ............................................................................................................................................................. 45
7.1. Before you begin .......................................................................................................................................... 45
7.2. For your safety read before lighting ............................................................................................................. 46
7.3. Lighting instructions..................................................................................................................................... 47
7.4. To turn of gas to insert / ZC-fireplace .......................................................................................................... 48
7.5. Starting the insert / ZC-fireplace for the first time ....................................................................................... 48
7.6. Adjusting the flame height ........................................................................................................................... 48
7.7. Adjusting the blower speed (optional).......................................................................................................... 50
7.8. Normal operating sounds.............................................................................................................................. 51
8. Maintenance (for qualified service personnel only) ........................................................................................... 52
8.1. Maintaining your insert / ZC-fireplace’s appearance ................................................................................... 52
8.2. Annual service procedure ............................................................................................................................. 52
Содержание 70 gas insert / ZC-fireplace
Страница 13: ...13 NOTE In Canada you can install the insert ZC fireplace up to 4500 ft without changing the orifice...
Страница 20: ...20 4 4 Approved venting configurations for vertical terminations Left Damper Right damper...
Страница 32: ...32 Left Damper Right damper...
Страница 33: ...33 5 13 Approved venting configurations for vertical terminations...
Страница 34: ...34 Left Damper Right damper...
Страница 49: ...49...
Страница 60: ...60 Use a 3 mm hexagon key and a 13 mm open end wrench...
Страница 61: ...61 9 3 Wiring diagram for blower 120 Volt Diagram 4...
Страница 64: ...64 11 Safety label...