39
1. When the unit is in place, mount the trim by pushing it into the springs. The springs are located on both sides
and the top of the unit. See Figure 2. It is possible to mount the trim with skrews for a firmer grip.
2. Mount the door lifter. Use two bolts, three washers and a nut as shown in Figure 12. The door lifter can later
be adjusted, to level the door when it is closed. The door lifter can be mounted on the left or right side of the
unit, as shown in Figure 11.
3. Mount the magnet. Use two bolts and two washers. as shown in Figure 13. The magnet must be mounted on
the same side as the door lifter.
Figure 12
Figure 13
Содержание 70 gas insert / ZC-fireplace
Страница 13: ...13 NOTE In Canada you can install the insert ZC fireplace up to 4500 ft without changing the orifice...
Страница 20: ...20 4 4 Approved venting configurations for vertical terminations Left Damper Right damper...
Страница 32: ...32 Left Damper Right damper...
Страница 33: ...33 5 13 Approved venting configurations for vertical terminations...
Страница 34: ...34 Left Damper Right damper...
Страница 49: ...49...
Страница 60: ...60 Use a 3 mm hexagon key and a 13 mm open end wrench...
Страница 61: ...61 9 3 Wiring diagram for blower 120 Volt Diagram 4...
Страница 64: ...64 11 Safety label...