SBS System – SB-1000 Operation
21
Fixed Position Manual Balance
1) Stop Spindle - This screen requests the operator to stop the spindle. The Stop Spindle icon flashes as a
reminder. This screen stays until the control detects that the spindle rotation has stopped.
2a) Apply Weights,
Zero Phase
- Once the spindle is stopped, this screen shows the operator how to
place the weight.
During the Zero Phase the weights must be removed.
2b) Apply Weights,
Test Phase
- During the Test Phase a test weight must be added (
+ ) at position 1.
The number inside the Weight icon shows the position number where weight is to be added. The value of
the test weight is shown.
During the Test Phase pressing Manual (note
icon) will
display this screen, allowing the test weight value to be edited.
The weight units can also be selected from g, oz, lb, kg, and
nothing.
It is essential to enter an accurate value for the test weight.
When done editing press to save changes and return to the
Apply Weights screen above.
2c) Apply Weights,
Solution Phase
- The weight positions and masses should be changed as shown to bring
the balance to a minimum.
Weight change display can be either additive (
+
) or absolute (
= )
. Press Manual button to
toggle between these options (note
icon). This selection will remain active until changed. Additive
weight display (
+ ) shows what weight changes should be made to achieve balance, with all previously
placed weights on the grinder remaining in place. Absolute weight display (
= ) shows what weight
changes should be made to achieve balance, assuming all previously placed weights will be removed.
Additive Weight Change
Absolute Weight Change