Data logger (automatic mode)
This mode is fully programmable by the user (it is necessary to programme the number of samples to be taken, the
sampling time for each sample and the printing mode).
When the Flue gas analysis begins, the instrument automatically executes and records the number of sample analyses
programmed and sets the time between each of them according to the programmed time. Once the analysis is
complete (indicated by an audible alarm), if the printing option is on
in the "
Manual printing
" mode, the instrument will display the average of the analysed samples with the
possibility of recalling each of them and then, it is possible to perform the printing (total, complete, etc.).
On the contrary, if the printing option is set to "
Automatic Printing
", the instrument will automatically print the
analyses, according to the current printing schedule, without displaying the average analysis.
Caution: in automatic mode, opacity category, draught and ambient CO measurements must be taken
before starting the Flue gas analysis.
Manual: manual analysis mode
Memory selection mode
Manual:
the memory selection must be done manually using the
"Select"
parameter
Auto:
the selection of the memory on which the measurements performed will be stored and the Flue gas analysis
will be proposed automatically when the instrument is started up.
Delete
Allows you to delete the contents of each of the memories or all 99 memories
Usage %
With this menu, the user can display how full the memory is ((displayed as a percentage).