All circuits are designated by their version and date. The program periodically checks the
memory content. The program run is supervised by hardware means. If a memory error
occurs, the trouble signal is generated. In case of a run-time error, the processor is restarted.
7. History of the manual updates
Given below is a description of changes as compared with the manual for the control panel
with firmware in version v1.04.
D
ATE
P
ROGRAM
VERSION
I
NTRODUCED CHANGES
2007-08
1.05
•
Added information on SIA, a new format of transmission to monitoring station (p. 4).
•
Added information on a new method of zone configuration: the zone status can
change as the output status changes (p. 5 and 23).
•
Added information on new devices supported by the control panel (p. 7-9).
•
Added information on the optional connection of roller shutter motion detectors
(rope detectors) and vibration detectors to the CA-64 E and CA-64 EPS
expanders (modules in the version manufactured from 2007) (p. 7, 7 and 23).
•
Modified contents and figures in the section on connecting expansion modules to
the control panel (p. 18).
•
Added information on the optional programming of resistor values for EOL and
2EOL configuration in case of zones in the CA-64 E and CA-64 EPS expanders
(modules in the version manufactured from 2007) (p. 22).
2008-05 1.06
•
Section "General features of control panels" has been modified (p. 3).
•
Information on INT-RX data converter has been added (p. 7).
•
Section "Control panel installation" has been modified and renamed into "System
installation" (p. 9):
−
section "Installation plan" has been added (p. 9);
−
section "Estimation of system current consumption” has been added (p. 9);
−
section "Cabling" has been added (p. 9);
−
section "Installation of control panel mainboard” has been added (p. 10);
−
section "Connecting LCD keypads" has been modified and renamed into
"Connecting LCD keypads and other devices to keypad bus" (p. 14);
−
section "Connecting expansion modules" has been modified and renamed into
"Connecting devices to expander bus" (p. 18);
−
section "Connection of sirens" has been modified (p. 26);
−
section "Connection of telephone line” – information on connecting dialer
protection terminal has been added (p. 28);
−
section "Connection of voice synthesizers" has been modified (p. 28);
−
figures in section "Connection of printer" have been changed (p. 28);
−
section "Connection of power supply" has been modified (p. 29);
−
section "Starting the control panel" has been modified (p. 30).