WARNINGS
For safety reasons, the alarm system should only be installed by qualified personnel.
In order to avoid the risk of electric shock, read carefully this manual before proceeding to
installation. Any connections should only be made in deenergized state, i.e. with power
supply disconnected.
The control panel should be connected to
PSTN (analog) lines only
. Connecting the
telephone circuit directly to digital network (e.g. ISDN) will cause damage to the equipment.
The alarm system may comprise dangerous devices, therefore it is necessary that its
components be kept so as to prevent unauthorized access to the equipment.
If the service operations consist in fuse replacement, they must only be carried out with
supply voltage disconnected. Only fuses having identical parameters with the original ones
can be used for the replacement.
It is recommended that the manufacturer’s prescribed housings and power supply units be
used.
Making any construction changes or unauthorized repairs is prohibited. This applies, in
particular, to modification of assemblies and components.
CAUTION!
It is impermissible to connect a fully discharged battery (with voltage on unloaded terminals
less than 11 V) to the alarm panel. In order to avoid equipment damage, the fully
discharged/never used battery should be precharged by means of a suitable charger.
The batteries used in the alarm systems contain lead. When used-up, the batteries must not
be thrown away, but disposed of as required by the existing regulations (European Directives
91/157/EEC and 83/86/EEC).
DECLARATION OF CONFORMITY
Products:
CA424P, CA832, CA16128P
- mainboards of INTEGRA control
panels.
- INTEGRA 24
- INTEGRA 32
- INTEGRA 64
- INTEGRA 128
Manufacturer:
SATEL spó
ł
ka z o.o.
ul. Schuberta 79
80-172 Gda
ń
sk, POLAND
tel. (+48 58) 320-94-00
fax. (+48 58) 320-94-01
Product description:
Mainboards for alarm control panels intended for use in intruder alarm systems.
These products are in conformity with the following EU Directives:
LVD
73/23/EEC+93/68/EEC
EMC
89/336/EWG + 91/263/EEC, 92/31EEC, 93/68/EEC
R&TTE
1999/5/EC (network connection, TBR21)
The product meets the requirements of harmonized standards:
LVD: EN 50131-1:1997; EN 50131-6:1997; EN60950:2000, EN60335-1:1994/A1:1996 Annex B
EMC: EN 55022:1998; EN 61000-3-2/-3; EN 50130-4:1995, EN 61000-4-2/-3/-4/-5/-6/-11
R&TTE: TBR 21(1998)
Gda
ń
sk, Poland
07.03.2005
Head of Test Laboratory
:
Micha
ł
Konarski
Latest EC declaration of conformity and product approval certificates are available for downloading on
website
www.satel.pl
The INTEGRA alarm control panels meet requirements as per CLC/TS 50131-3, Grade 3,
and have been certified by Det Norske Veritas Certification AS, Norway.