INTEGRA Installer
Manual
17
4.5.1.1 Programming keypad address by means of service function
1. By means of any supported keypad, enter the control panel service mode
([SERVICE CODE][*]
Æ
S
ERVICE MODE
).
2. Start the function K
EYPADS ADDR
. (
Æ
S
TRUCTURE
Æ
H
ARDWARE
Æ
I
DENTIFICATION
Æ
K
EYPADS ADDR
.).
3. The message shown in Figure 9 will appear on display of all keypads connected to
the control panel.
Fig.
9
.
Programming the keypad address.
4. Enter a proper address in the selected keypad(s). The address change will be
confirmed by four short and one long beeps.
5. To terminate the address change function, press the [*] key. The function will be
terminated automatically after 2 minutes from being started. Termination of the
function is equivalent to quitting the service mode and restarting the keypad.
4.5.1.2 Programming keypad address without entering service mode
This method of address programming is particularly useful when – due to repeating
addresses – the keypad support has been disabled and entering the service mode is
impossible.
1. Disconnect keypad power supply (KPD) and signal wires CKM and DTM.
2. Short the keypad terminals CKM and DTM.
3. Switch on keypad power supply.
4. The text shown in fig. 9 will appear on the display.
5. Enter a new address. The keypad will confirm execution of the function by four short
and one long beeps. If it is necessary to change the entered address, press the [*]
key (keypad restart will follow and the text shown in fig. 9 will again be displayed).
6. Disconnect the keypad power supply.
7. Open the keypad terminals CKM and DTM.
8. Connect the keypad correctly to the control panel.
4.5.2 Numeration of keypad zones
Numbers of
Z1,
Z2
zones in security system
INTEGRA 24
INTEGRA 32
INTEGRA 64
INTEGRA 128
Keypad
address
Z1 Z2 Z1 Z2 Z1 Z2 Z1 Z2
0
5 6 25 26 49 50 113 114
1
7 8 27 28 51 52 115 116
2
21 22 29 30 53 54 117 118
3
23 24 31 32 55 56 119 120
4
57 58
121
122
5
59 60
123
124
6
61 62
125
126
7
63 64
127
128
Table 2.
n=0...7,
current address of the
keypad