4.8 Connection of sirens
The method of connection depends on the output type (high- or low-current). The high-
current outputs are more suitable for control of sirens without their own power supply, while
the low-current outputs – for control of sirens with their own power supply. The outputs are to
be programmed as required.
INTEGRA 32
STO
TMP
SENS TMP
TMP
STA
SP-4001
Fig. 20
.
Connection of siren without own power supply to high-current outputs (by the
example of SP-4001 and INTEGRA 32 control panel). Optical signaling is triggered by OUT1
output, and audible signaling by OUT2 output (high-current outputs with normal polarization:
when activated, +12 V voltage is supplied). Z1 is programmed as tamper zone (NC type,
function 9. 24
H TAMPER
).
INTEGRA 32
COM AUX
Z8
OUT3
OUT4
COM
GND
STO
+12V
TMP
SENS TMP
TMP
STA
SP-4002
Fig. 21.
Connection of siren with own power supply to low-current outputs (by the example of
SP-4002 and INTEGRA 32 control panel). Audible signaling is triggered by OUT3 output, and
optical signaling by OUT4 output (low-current outputs with normal polarization: when
activated, they are shorted to ground). Z8 is programmed as tamper zone (NC type, function
9. 24
H TAMPER
).