SATEL ACU-270
15
tolerance.
AVD-100
– wireless vibration detector and magnetic contact. The following is to be
programmed:
active reed switch [first zone];
sensitivity of vibration detector (registering a single vibration meeting the sensitivity
criterion will cause alarm) [second zone];
the number of pulses which, if registered by vibration detector will cause alarm (the
pulses need not meet the sensitivity criterion) [second zone].
Working parameters of the vibration detector are independently analyzed. The
detector can trigger alarm after registering a single, strong vibration caused by
a powerful impact, and also on registering several slight vibrations caused by a series
of weak strikes.
ASP-100
– wireless outdoor siren. The following is to be programmed:
type of acoustic signaling;
maximum duration of signaling.
ASP-105
– wirelessly triggered outdoor siren. The following is to be programmed:
type of acoustic signaling;
maximum duration of acoustic signaling.
ASP-205
– wireless indoor siren. Signaling parameters can be programmed for both
positions occupied by the siren (thus allows to program two different signaling types):
maximum duration of signaling;
type of acoustic signaling;
optical signaling option.
ASW-100 E
/
ASW-100 F
– 230 V AC wireless controller. Operating mode can be
programmed.
6.3.2 Programming in the INTEGRA / INTEGRA Plus system
DLOADX program
You can program the wireless devices in the “Structure” window, “Hardware” tab, after
clicking on the controller name in the list of devices (Fig. 4). Before making any changes,
click on the “Read” button, and after making the changes – on the “Write” button (the data
relating to wireless devices are not read and saved after clicking on the
button in the
DLOADX program main menu).
ARU
In the “ARU” column:
– leave the field blank, if the device is to communicate directly to the controller;
– enter the ARU-100 repeater number in the list of wireless devices, if the device is to
communicate to the controller via the repeater (the ARU-100 repeater takes up two
positions on the list of devices – enter the number of the first of them).
Configuration
Described below is how the additional parameters and options should be programmed in the
“Configuration” column.
AGD-100
– enter a digit from the 1 to 3 range to set the sensitivity (1 – low, 2 – medium,
3 - high).