background image

SATEL ACU-270 

23 

4.  When the keyfob serial number is displayed in the window, click on the “OK” button. The 

“New” window will close. The serial number of the new keyfob will be shown in the “S/N” 
column. 

Assigning new function to the keyfob button (combination of buttons) 

1.  Click on the field corresponding to the button (combination of buttons) to which you want 

to assign a zone. 

2.  Enter the zone number and press ENTER to confirm. 
3.  Using the SPACE key enable/disable the event generating function. If the 

 symbol is 

displayed next to the zone number, the event will not be saved after pressing the button / 
combination of buttons (if no symbol is displayed, the event will be saved). 

Assigning outputs to the LEDs 

1.  Click on the field in the “LED” column. 
2.  Using the keyboard, enter up to 3 digits. Each of the digits must correspond to the number 

of field with output selected for confirmation (on the window right side) i.e. it can be from 
the 1 to 8 range. The names of outputs in fields designated with these digits will be shown 
in bold-type face. 

8.1.2  Removing the APT-100 keyfob by means of the DLOADX program 

1.  Click on the field in “S/N” column next to the name of user whose keyfob is to be 

removed. 

2.  Click on the “Delete” button. 
3.  In the window which will be displayed, click on the “Yes” button to confirm that you want to 

remove the keyfob. The keyfob serial number shown in the “S/N” column will be erased. 

8.2  Keyfobs in the VERSA / VERSA Plus / VERSA IP system 

The functions which can be started using the keyfobs and the information that can be 
presented on the LEDs are described in manuals for the VERSA / VERSA Plus / VERSA IP 
control panels. After a keyfob has been added, its settings will be configured automatically, 
based on the user schedule. These settings can be modified (different functions can be 
assigned to the buttons / combination of buttons and different information to the LEDs). 
The user manual for VERSA / VERSA Plus / VERSA IP control panels describes the 
procedures for adding and editing the user by means of the keypad, during which you can 
add or remove the keyfob and program its settings. 
In the DLOADX program, you can add and delete keyfobs in the “Versa – Structure” window, 
“Hardware” tab, after clicking on the controller name in the list of devices, and then on the 
“Keyfobs” tab (Fig. 7). Before making any changes, click on the “Read” button, and after 
making the changes – on the “Write” button (the data relating to keyfobs are not read after 

clicking on the 

 button or saved after clicking on the 

 button in the DLOADX 

program main menu). 

Removal of a keyfob by means of the keypad will not erase its settings (the functions 
assigned to the buttons). When added to the user, the new keyfob will have the same 
settings as the deleted one. 

You can remove all keyfobs, including their settings, by means of the R

EM

.ABAX

 KFBS

 

function available in the service mode in the keypad (

2. H

ARDWARE

 

1. K

PDS

.

 

&

 

EXPS

.

 

8. R

EM

.ABAX

 KFBS

). 

Содержание ACU-270

Страница 1: ...ABAX WIRELESS SYSTEM CONTROLLER ACU 270 Firmware version 5 02 acu 270_en 03 16 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...er the warranty SATEL s goal is to continually upgrade the quality of its products which may result in some changes of their technical specifications and firmware The current information on the introd...

Страница 3: ...ASP 100 wireless outdoor siren Irrespective of in conjunction with which control panel the controller is used you can select for some wireless devices whether the wireless device will take up one or t...

Страница 4: ...Programming the wireless devices 13 6 3 1 Parameters and options 13 6 3 2 Programming in the INTEGRA INTEGRA Plus system 15 6 3 3 Programming in the VERSA VERSA Plus VERSA IP system 17 6 4 Specific ch...

Страница 5: ...unnecessary Additionally the controller allows to operate the alarm system using the ABAX system two way keyfobs The name plate of the controller is located on the enclosure base After installation of...

Страница 6: ...al switches in ON position are shown in Table 1 The sum of numerical values assigned to switches 1 5 means the address set on the device The address must be different from that on the other devices co...

Страница 7: ...ncy the lower the number of devices that can work within each other s range 1 Open the enclosure of the controller Fig 2 2 Set the DIP switches as required see DIP switches 3 Place the enclosure base...

Страница 8: ...he module will be identified as ACU 100 5 Programming the controller Programming of the controller is carried out by means of the control panel using the LCD keypad in service mode INTEGRA INTEGRA Plu...

Страница 9: ...mber of tamper alarms from the module to three is disabled the feature prevents multiple logging of the same events and applies to successive uncleared alarms Response period communication with wirele...

Страница 10: ...the ASP 105 and ASP 205 sirens The test mode is started ended during polling which results in a delay its duration depending on the programmed response period The test mode will be turned off automati...

Страница 11: ...quality You can install the device permanently only after reaching the optimum level of radio signal The wireless devices must be registered to the alarm system This can be done using the LCD keypad o...

Страница 12: ...tor 20 unused unavailable 5 AMD 101 detector 21 AMD 101 detector 21 unused unavailable 6 22 AMD 101 detector 22 unused unavailable 7 23 unused unavailable 23 unused unavailable 8 ASP 105 siren 8 24 AS...

Страница 13: ...t for the controller If when new wireless devices have been added to the controller it turns out that next addresses are needed and these are taken up by other devices successful completion of the exp...

Страница 14: ...the device 7 digit serial number and press the key The serial number can be found on the electronics board or on the enclosure Each ARF 100 radio signal level tester has serial number 0000500 3 When...

Страница 15: ...t will appear on the display asking you whether the device is to be removed the device type and serial number will be shown Press the key 1 The device will be deleted 4 A message on the display will i...

Страница 16: ...magnetic contact The active reed switch is to be selected AMD 102 wireless magnetic contact with input for roller shutter detector The following is to be programmed active reed switch first zone numbe...

Страница 17: ...ons occupied by the siren thus allows to program two different signaling types maximum duration of signaling type of acoustic signaling optical signaling option ASW 100 E ASW 100 F 230 V AC wireless c...

Страница 18: ...100 enter 2 digits 1st digit sensitivity 1 low 2 medium or 3 high 2nd digit pet immunity option 0 disabled or 1 enabled ARD 100 enter a number from the 1 to 16 range to determine sensitivity 1 minimu...

Страница 19: ...ans of the DLOADX program 6 3 3 Programming in the VERSA VERSA Plus VERSA IP system DLOADX program You can configure wireless devices in the Versa Structure window Hardware tab after clicking on the c...

Страница 20: ...horter than in those which are periodically switched to the passive mode However if the specific character of a detector or its installation place is such that the number of violations is low switchin...

Страница 21: ...n ASP 105 installing the battery ASP 205 It enables installation work to be carried out Opening the tamper switch will not trigger loud signaling but information on tamper will be sent when in service...

Страница 22: ...rcuit if reverse polarity of the output has been programmed the circuit will be deenergized Depending on the operating mode information on the button status mode 0 or on the electric circuit status mo...

Страница 23: ...keyfob data In the case of the DLOADX program to write to a new controller the data on APT 100 keyfobs already assigned to the users open the Keyfobs ABAX window and INTEGRA 128 WRL click on the Write...

Страница 24: ...d to the user the new keyfob will have the same settings as the deleted one You can remove all keyfobs including their settings by means of the REM ABAX KEYFOB function available in the service mode i...

Страница 25: ...umber shown in the S N column will be erased 8 2 Keyfobs in the VERSA VERSA Plus VERSA IP system The functions which can be started using the keyfobs and the information that can be presented on the L...

Страница 26: ...presented on the LEDs 1 Click on the field corresponding to the selected LED 2 Right click on your mouse A drop down menu will appear in which you are to select the new information 9 Specifications Su...

Страница 27: ...added Information on ASP 100 siren has been added p 8 9 13 and 15 Information on AOD 200 detector has been added p 8 14 and 16 Note about wireless devices which can take up one or two positions on th...

Отзывы: