10 ACU-270 

SATEL 

When adding and removing the wireless devices, remember that the identification function 
registers zones and outputs by groups of 8. Already after adding one wireless device which 
takes up 1 zone, the control panel will reserve 8 zones in the system for wireless devices. 
The LCD keypad makes it possible to select the zone to which that device will be assigned. 
Observe continuity, i.e. avoid leaving any gaps in the list, which will later reduce the number 
of available zones in the system. Remember to preserve continuity also when removing 
wireless devices. For example, if the devices registered in the controller occupy 9 positions 
on the list, then 16 zones (2x8) are reserved in the system. After removal of the device which 
occupied position 7 on the list, there will still be 16 zones (2x8) reserved in the system for 
wireless devices, although 8 positions are actually taken up on the list of wireless devices 
(see: Table 2). In such a case, it is recommended that the last devices be removed from the 
list and then added to the system again, so as to fill up the gap in the list and reduce the 
number of zones reserved for wireless devices. 
 

INTEGRA / INTEGRA Plus 

ACU-270 

zones 

outputs 

It.. 

list of devices 

 

No 

device 

No

device 

APD-100 detector 

17  APD-100 detector 

17  unused/unavailable 

APD-100 detector 

18  APD-100 detector 

18  unused/unavailable

 

AMD-100 detector 

19  AMD-100 detector 

19  unused/unavailable

 

AMD-100 detector 

20  AMD-100 detector 

20  unused/unavailable

 

AMD-101 detector 

21  AMD-101 detector 

21  unused/unavailable

 

6 ^ 

22 

AMD-101 

detector 

22 

unused/unavailable

 

 23 

unused/unavailable 23 

unused/unavailable

 

8 ASP-105 

siren 

24 ASP-105 

siren 

24 ASP-105 

siren 

9  ^ 

25 ASP-105 

siren 

25 ASP-105 

siren 

10   26 

unused/unavailable 26 

unused/unavailable

 

11   27 

unused/unavailable 27 

unused/unavailable

 

12   28 

unused/unavailable 28 

unused/unavailable

 

13   29 

unused/unavailable 29 

unused/unavailable

 

14   30 

unused/unavailable 30 

unused/unavailable

 

15   31 

unused/unavailable 31 

unused/unavailable

 

16   

32  unused/unavailable 32 

unused/unavailable

 

Table 2. An example of how the wireless devices should not be registered. For devices taking 

up 8 positions, the system must reserve 16 zones and 16 outputs, as well as 2 addresses.  

 

INTEGRA / INTEGRA Plus 

ACU-270 

zones 

outputs 

It. 

list of devices 

 

No 

device 

No

device 

ASP-105 siren 

17  ASP-105 siren 

17  ASP-105 siren 

2  ^ 

18 ASP-105 

siren 

18 ASP-105 

siren 

APD-100 detector 

19  APD-100 detector 

19  unused/unavailable

 

APD-100 detector 

20  APD-100 detector 

20  unused/unavailable

 

AMD-100 detector 

21  AMD-100 detector 

21  unused/unavailable

 

AMD-100 detector 

22  AMD-100 detector 

22  unused/unavailable

 

AMD-101 detector 

23  AMD-101 detector 

23  unused/unavailable

 

8 ^ 

24 AMD-101 

detector 

24 unused/unavailable

 

Table 3. An example of how to correctly register the wireless devices (compare also Fig. 5). 

For 8 devices, the system has reserved 8 zones and 8 outputs, as well as 1 address. 

 
In case of devices which, in addition to zones, also take up outputs, it is recommended that 
you add them to the system first. This will allow you to maintain the continuity of use of not 

Содержание ACU-270

Страница 1: ...ABAX WIRELESS SYSTEM CONTROLLER ACU 270 Firmware version 5 02 acu 270_en 03 16 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...er the warranty SATEL s goal is to continually upgrade the quality of its products which may result in some changes of their technical specifications and firmware The current information on the introd...

Страница 3: ...ASP 100 wireless outdoor siren Irrespective of in conjunction with which control panel the controller is used you can select for some wireless devices whether the wireless device will take up one or t...

Страница 4: ...Programming the wireless devices 13 6 3 1 Parameters and options 13 6 3 2 Programming in the INTEGRA INTEGRA Plus system 15 6 3 3 Programming in the VERSA VERSA Plus VERSA IP system 17 6 4 Specific ch...

Страница 5: ...unnecessary Additionally the controller allows to operate the alarm system using the ABAX system two way keyfobs The name plate of the controller is located on the enclosure base After installation of...

Страница 6: ...al switches in ON position are shown in Table 1 The sum of numerical values assigned to switches 1 5 means the address set on the device The address must be different from that on the other devices co...

Страница 7: ...ncy the lower the number of devices that can work within each other s range 1 Open the enclosure of the controller Fig 2 2 Set the DIP switches as required see DIP switches 3 Place the enclosure base...

Страница 8: ...he module will be identified as ACU 100 5 Programming the controller Programming of the controller is carried out by means of the control panel using the LCD keypad in service mode INTEGRA INTEGRA Plu...

Страница 9: ...mber of tamper alarms from the module to three is disabled the feature prevents multiple logging of the same events and applies to successive uncleared alarms Response period communication with wirele...

Страница 10: ...the ASP 105 and ASP 205 sirens The test mode is started ended during polling which results in a delay its duration depending on the programmed response period The test mode will be turned off automati...

Страница 11: ...quality You can install the device permanently only after reaching the optimum level of radio signal The wireless devices must be registered to the alarm system This can be done using the LCD keypad o...

Страница 12: ...tor 20 unused unavailable 5 AMD 101 detector 21 AMD 101 detector 21 unused unavailable 6 22 AMD 101 detector 22 unused unavailable 7 23 unused unavailable 23 unused unavailable 8 ASP 105 siren 8 24 AS...

Страница 13: ...t for the controller If when new wireless devices have been added to the controller it turns out that next addresses are needed and these are taken up by other devices successful completion of the exp...

Страница 14: ...the device 7 digit serial number and press the key The serial number can be found on the electronics board or on the enclosure Each ARF 100 radio signal level tester has serial number 0000500 3 When...

Страница 15: ...t will appear on the display asking you whether the device is to be removed the device type and serial number will be shown Press the key 1 The device will be deleted 4 A message on the display will i...

Страница 16: ...magnetic contact The active reed switch is to be selected AMD 102 wireless magnetic contact with input for roller shutter detector The following is to be programmed active reed switch first zone numbe...

Страница 17: ...ons occupied by the siren thus allows to program two different signaling types maximum duration of signaling type of acoustic signaling optical signaling option ASW 100 E ASW 100 F 230 V AC wireless c...

Страница 18: ...100 enter 2 digits 1st digit sensitivity 1 low 2 medium or 3 high 2nd digit pet immunity option 0 disabled or 1 enabled ARD 100 enter a number from the 1 to 16 range to determine sensitivity 1 minimu...

Страница 19: ...ans of the DLOADX program 6 3 3 Programming in the VERSA VERSA Plus VERSA IP system DLOADX program You can configure wireless devices in the Versa Structure window Hardware tab after clicking on the c...

Страница 20: ...horter than in those which are periodically switched to the passive mode However if the specific character of a detector or its installation place is such that the number of violations is low switchin...

Страница 21: ...n ASP 105 installing the battery ASP 205 It enables installation work to be carried out Opening the tamper switch will not trigger loud signaling but information on tamper will be sent when in service...

Страница 22: ...rcuit if reverse polarity of the output has been programmed the circuit will be deenergized Depending on the operating mode information on the button status mode 0 or on the electric circuit status mo...

Страница 23: ...keyfob data In the case of the DLOADX program to write to a new controller the data on APT 100 keyfobs already assigned to the users open the Keyfobs ABAX window and INTEGRA 128 WRL click on the Write...

Страница 24: ...d to the user the new keyfob will have the same settings as the deleted one You can remove all keyfobs including their settings by means of the REM ABAX KEYFOB function available in the service mode i...

Страница 25: ...umber shown in the S N column will be erased 8 2 Keyfobs in the VERSA VERSA Plus VERSA IP system The functions which can be started using the keyfobs and the information that can be presented on the L...

Страница 26: ...presented on the LEDs 1 Click on the field corresponding to the selected LED 2 Right click on your mouse A drop down menu will appear in which you are to select the new information 9 Specifications Su...

Страница 27: ...added Information on ASP 100 siren has been added p 8 9 13 and 15 Information on AOD 200 detector has been added p 8 14 and 16 Note about wireless devices which can take up one or two positions on th...

Отзывы: