47
Data log number
Registers (see Table 5-67)
TOU Monthly Profile Log. Energy Reg. #2
30376-30415
TOU Monthly Profile Log. Energy Reg. #3
30416-30455
TOU Monthly Profile Log. Energy Reg. #4
30456-30495
TOU Monthly Profile Log. Energy Reg. #5
30496-30535
TOU Monthly Profile Log. Energy Reg. #6
30536-30575
TOU Monthly Profile Log. Energy Reg. #7
30576-30615
TOU Monthly Profile Log. Energy Reg. #8
30616-30655
Reserved 30656-30975
TOU Monthly Profile Log. Max. Demand Reg. #1
30976-31015
TOU Monthly Profile Log. Max. Demand Reg. #2
31016-31055
TOU Monthly Profile Log. Max. Demand Reg. #3
31056-31095
Reserved 31096-31615
TOU Daily Profile Log. Energy Reg. #1
31616-31655
TOU Daily Profile Log. Energy Reg. #2
31656-31695
TOU Daily Profile Log. Energy Reg. #3
31696-31735
TOU Daily Profile Log. Energy Reg. #4
31736-31775
TOU Daily Profile Log. Energy Reg. #5
31776-31815
TOU Daily Profile Log. Energy Reg. #6
31816-31855
TOU Daily Profile Log. Energy Reg. #7
31856-31895
TOU Daily Profile Log. Energy Reg. #8
31896-31935
Reserved 31936-32255
TOU Daily Profile Log. Max. Demand Reg. #1
32256-32295
TOU Daily Profile Log. Max. Demand Reg. #2
32296-32335
TOU Daily Profile Log. Max. Demand Reg. #3
32336-32375
Reserved 32376-32895
If data log partition #7 is configured as a TOU monthly profile partition, registers 29936-29975 are mapped to
registers 30336-30375 for the first TOU monthly profile sub-partition allocated for TOU energy register #1, or if this
register is not configured, for the following first available TOU register.
If data log partition #8 is configured as a TOU daily profile partition, registers 29976-30015 are mapped to
registers 31616-31655 for the first TOU daily profile sub-partition allocated for TOU energy register #1, or if this
register is not configured, for the following first available TOU register.
Table 5-67 Data Log Window Registers
Parameter
Offset
Type
R/W
Range
Record status
+0
UINT16 R
Bit-mapped register:
bit 0 = 1 - the end record is being read (the end of a
log file reached)
bit 1 = 1 - reading after the end of file: the read
pointer has rolled over the end of a log file, i.e., the
file is being re-read from the beginning. This bit is
cleared when a new record is being read, or the read
sequence has changed by overwriting the partition
pointer.
bit 8 = 1 - no records logged in the partition
bit 9 = 1 - the record is corrupted
bit 15 = 1 - read error (detailed by bits 8-9)
Record sequence number
+1
UINT16 R
0 to 65535 (increments modulo 65536 with each log)
Timestamp
1
+2, 3
UINT32 R
Local time (UNIX-style)
Fractional seconds portion of timestamp +4
UINT16 R
0-990 ms (at 10 ms resolution)
Event setpoint ID
+5
UINT16 R
0 = TOU profile log, 1 to 16
Parameter #1 value
2
+6, 7
INT32
R
See Table 5-2
Parameter #2 value
2
+8, 8
INT32
R
See Table 5-2
Parameter #3 value
2
+10, 11 INT32
R
See Table 5-2
Parameter #4 value
2
+12, 13 INT32
R
See Table 5-2
Parameter #5 value
2
+14, 15 INT32
R
See Table 5-2
Parameter #6 value
2
+16, 17 INT32
R
See Table 5-2
Parameter #7 value
2
+18, 19 INT32
R
See Table 5-2
Parameter #8 value
2
+20, 21 INT32
R
See Table 5-2
Parameter #9 value
2
+22, 23 INT32
R
See Table 5-2
Parameter #10 value
2
+24, 25 INT32
R
See Table 5-2
Parameter #12 value
2
+26, 27 INT32
R
See Table 5-2
Parameter #13 value
2
+28, 29 INT32
R
See Table 5-2
Parameter #13 value
2
+30, 31 INT32
R