Trigger parameter
Trigger
Type
Unit
2
Limit/scale
1
Con-
ID
Low
High
version
High voltage unbalance
8
0x1503
UINT16
1%
0
300
LIN3
High present demands
High volt demand L1/L12
5
0x1600 UINT16 0.1V/1V
0
Vmax LIN3
High volt demand L2/L23
5
0x1601 UINT16 0.1V/1V
0
Vmax LIN3
High volt demand L3/L31
5
0x1602 UINT16 0.1V/1V
0
Vmax LIN3
High ampere demand L1
0x1603 UINT16 0.01A
0
Imax LIN3
High ampere demand L2
0x1604 UINT16 0.01A
0
Imax LIN3
High ampere demand L3
0x1605 UINT16 0.01A
0
Imax LIN3
High block kW import demand
E
0x1606 UINT16 0.001kW/1kW
0
Pmax LIN3
High block kvar import demand
E
0x1607 UINT16 0.001kvar/1kvar 0
Pmax LIN3
High block kVA demand
E
0x1608 UINT16 0.001kVA/1kVA 0
Pmax LIN3
High sliding window kW import demand
E
0x1609 UINT16 0.001kW/1kW
0
Pmax LIN3
High sliding window kvar import demand
E
0x160A UINT16 0.001kvar/1kvar 0
Pmax LIN3
High sliding window kVA demand
E
0x160B UINT16 0.001kVA/1kVA 0
Pmax LIN3
High accumulated kW import demand
E
0x160F UINT16 0.001kW/1kW
0
Pmax LIN3
High accumulated kvar import demand
E
0x1610 UINT16 0.001kvar/1kvar 0
Pmax LIN3
High accumulated kVA demand
E
0x1611 UINT16 0.001kVA/1kVA 0
Pmax LIN3
High predicted kW import demand
E
0x1612 UINT16 0.001kW/1kW
0
Pmax LIN3
High predicted kvar import demand
E
0x1613 UINT16 0.001kvar/1kvar 0
Pmax LIN3
High predicted kVA demand
E
0x1614 UINT16 0.001kVA/1kVA 0
Pmax LIN3
High block kW export demand
E
0x1616 UINT16 0.001kW/1kW
0
Pmax LIN3
High block kvar export demand
E
0x1617 UINT16 0.001kvar/1kvar 0
Pmax LIN3
High sliding window kW export demand
E
0x1618 UINT16 0.001kW/1kW
0
Pmax LIN3
High sliding window kvar export demand
E
0x1619 UINT16 0.001kvar/1kvar 0
Pmax LIN3
High accumulated kW export demand
E
0x161A UINT16 0.001kW/1kW
0
Pmax LIN3
High accumulated kvar export demand
E
0x161B UINT16 0.001kvar/1kvar 0
Pmax LIN3
High predicted kW export demand
E
0x161C UINT16 0.001kW/1kW
0
Pmax LIN3
High predicted kvar export demand
E
0x161D UINT16 0.001kvar/1kvar 0
Pmax LIN3
Setpoint status
8
Setpoint #1 ON
0x7C00 UINT16
N/A
N/A
NONE
Setpoint #2 ON
0x7C01 UINT16
N/A
N/A
NONE
Setpoint #3 ON
0x7C02 UINT16
N/A
N/A
NONE
Setpoint #4 ON
0x7C03 UINT16
N/A
N/A
NONE
Setpoint #5 ON
0x7C04 UINT16
N/A
N/A
NONE
Setpoint #6 ON
0x7C05 UINT16
N/A
N/A
NONE
Setpoint #7 ON
0x7C06 UINT16
N/A
N/A
NONE
Setpoint #8 ON
0x7C07 UINT16
N/A
N/A
NONE
Setpoint #9 ON
0x7C08 UINT16
N/A
N/A
NONE
Setpoint #10 ON
0x7C09 UINT16
N/A
N/A
NONE
Setpoint #11 ON
0x7C0A UINT16
N/A
N/A
NONE
Setpoint #12 ON
0x7C0B UINT16
N/A
N/A
NONE
Setpoint #13 ON
0x7C0C UINT16
N/A
N/A
NONE
Setpoint #14 ON
0x7C0D UINT16
N/A
N/A
NONE
Setpoint #15 ON
0x7C0E UINT16
N/A
N/A
NONE
Setpoint #16 ON
0x7C0F UINT16
N/A
N/A
NONE
1
For parameter limits, see Note
1
to Table 5-1
2
When using direct wiring (PT Ratio = 1), voltages are transmitted in 0.1 V units, currents in 0.01 A units, and powers in
0.001 kW/kvar/kVA units. For wiring via PTs (PT Ratio > 1), voltages are transmitted in 1V units, currents in 0.01 A units,
and powers in 1 kW/kvar/kVA units.
3
The setpoint is operated when the actual phase sequence does not match the indicated phase rotation.
4
The actual frequency range is 45.00 - 65.00 Hz.
5
When the 4LN3 or 3LN3 wiring mode is selected, the voltages will be line-to-neutral; for any other wiring mode, they will be
line-to-line voltages.
6
Operate limit for the voltage disturbance trigger specifies the voltage deviation allowed in percentage of the nominal
secondary line-to-line voltage. The tested voltage refers to line-to-line voltage in 3OP2 and 3OP3 wiring modes, and to line-
to-neutral voltage in other modes. See Section 5.8, Basic Setup, for information on setting the nominal voltage in your
meter.
7
Available starting with F/W Version 4.87.
8
Available starting with F/W Version 4.88.2.
E
Available in the PM172E.