34
The red display LED is lit when one of four error conditions has been detected. E will appear in the LEFT display
and a fault value will appear in the RIGHT display.
- El = safety sensor fault: There is no communication between the Operator and the safety sensor. Check the
connections.
- E3 = button error: The controller is not responding to the program buttons. Consult the factory.
- E5 = battery fault: The battery is discharged, or missing. If the battery is discharged, charge it. If the battery is
missing or will not take a charge, install a new battery.
- E8 = Eprom error: the microprocessor has failed; replace the controller board.
Note: If the door does not perform properly
when first tested, it could be the result of
one of the following problems.
Troubleshooting common start up problems.
Problem
Cause
1
Door operator applies closing force
Control Point 14 is set to wrong value of 0 or 1.
when activated to open
Swap the value to change handing. Or…
Pulse disk was turned in the wrong direction
during programming.
2
Door does not fully close
Check pulse disk closed position.
3
Door moves a few inches and then
Operator force set too low for door weight.
stalls, restarts, stalls, etc.
Increase Control Point 3 value by 1 increment until
door opens smoothly.
4
Door operator does not operate
Jumper on terminal 10-11 missing
5
LED display reads E3, door operator
Jumper on terminal 1-2 missing
does not work
6
Door cycling without activation of
Check wiring of actuators
push plates (actuators)
7
Door delays before opening
Check actuator connection. If connected to
terminals 6 & 7, move to terminals 8 & 9.