Programming a Control Point
Control Points are programmed by means of the three pushbuttons,
S (Control Point Selection),
–
(Decrement), and A (Adjust control Point value).
Procedure
1.
Press and hold the S button until the yellow LED is lit (3 sec for a normal Control Point, 5 sec for a sealed
Control Point).
•
The number of the currently active Control Point is displayed
•
A signal dot appears in the right display
2.
To display the next higher Control Point number, press the S button; to display the next lower Control Point
number, press the - button.
3.
Select the Control Point to be adjusted
4.
When the number of the Control Point to be adjusted is displayed, press the A button.
•
The current value of the Control Point appears in the displays
•
The yellow LED flashes, except for a sealed Control Point
•
The signal dot disappears on the right display
5.
To increase the value of the Control Point, press the A button.
To decrease the value of the Control Point, press the - button.
6.
When the correct value is displayed, press the S button.
•
The value is stored in memory
•
The yellow LED remains lit but stops flashing
•
The next higher Control Point number is displayed
7.
When you have finished adjusting Control Point values, test door operation. If operation is
satisfactory, the door is ready for service.
Control
Description
Factory
Point
Setting
0
Back Check Angle
35
1
Full Open Door Angle (100° Max.)
42
2
Close check Starting Angle
15
3
Opening / Closing Force
4
5
Opening Speed
4
6
Back Check Speed
4
9
Closing Speed
3
10
Latch Speed
3
17
Delay before opening (delayed impulse)
15
PROGRAMMING A CONTROL POINT
Quick Reference: Commonly Adjusted Control Points
Содержание 2600 Series
Страница 29: ...28 ELECTRICAL WIRING Typical Application 1 ...
Страница 30: ...29 ELECTRICAL WIRING Typical Application 2 ...
Страница 31: ...30 ELECTRICAL WIRING Typical Application 3 ...
Страница 32: ...31 ELECTRICAL WIRING Typical Application 4 ...