When wiring controls for use as a simultaneous pair, all required inputs need to be
synchronized (connected) between Door #1 and Door #2 (shown as dotted lines in
above diagram).
•
Example shown above: Push plates are connected to inputs 8, 10 and 11 at door #1
and are connected via sync line to Door #2.
•
When using pairs of controls, N.C. inputs 12, 13 and 14 may be sync’d to each other,
OR each control may have its own jumpers installed. If any of these inputs are
required for the application, the jumper will be removed for the respective input – in
place of the jumper, a N.C. switching circuit will connected to Door #1, and a sync
line will be connected to Door #2.
•
For simultaneous pairs, each plug-in connector for the control is wired in parallel to
the On-Off-Hold switch located in the header end-cap. One switch will control both
doors.
•
All control adjustments (speed & time delay) must be made independently at each
control.
•
All dip switches at each control must be set independently and must match between
controls.