![Sargent and Greenleaf Touchless ADO Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/sargent-and-greenleaf/touchless-ado/touchless-ado_installation-manual_1199136042.webp)
SARGENT & GREENLEAF
■
WWW.SARGENTANDGREENLEAF.COM
[t] 800.826.7652
■ 859.885.9411 ■
E-mail: (Information Required)
■
One Security Dr. Nicholasville, Kentucky 40356
S&G TOUCHLESS ADO.docx REV - 08/2021
42
LOW ENERGY APPLICATION 1:
PUSH PLATES WITH APPROACH SIDE DOOR-MOUNTED SENSOR
•
Non-Swing Side (approach) door-mounted sensor is wired into the secondary activation input (13)
at the I/O board. It is a normally closed circuit. Remove factory jumper on terminal 13.
•
Door-mounted sensor will cause re-activation when in detection during the closing cycle.
•
Secondary activation input is disabled at the full closed door position.
•
Jumpers must be installed between terminal 8 and 12 & 14 if those inputs are not required for the
application. If they are used for the application, they must be connected to a N.C. circuit.
RED (+)
BLK (-)
(N/O)
(COM)
PUSH
TO OPEN
Push
Button
(Exterior)
WHT (COM)
GRN
(Closed
Loop)
(N/O)
(COM)
PUSH
TO OPEN
Push
Button
(Interior)
SDC AUTO-IR
Remove
Factory
Jumper 13
when using
Presence sensor
Содержание Touchless ADO