Time Input - Clock Settings - Sync-Wire Communication Protocol (3300 Only)
Inputs for Sync-wire protocols are located on the
upper-port block on the back of the clock. For this
manual, the ports in each block are listed as 1-9,
starting with port 1 on the left, and ending with
port 9 on the right.
There are two port blocks. In this manual, the block
on the left will be called J1, while the block on the
right will be called J2. Refer to the diagram
for details.
The diagrams on the following pages indicate how
wires should be run between the various ports on
the clock and the network to allow for the use of
Sync-wire protocols.
Before a clock can use these protocols, it must be
configured to accept the intended protocol as its
input through either the front buttons or sbdconfig.
Refer to the sections “
” or
59 Minute Correction
1
9 1
9
J2
J1
J1-
1 2 3 4 5 6 7
9
8
Neutral
Reset
110VAC or
230VAC Interface
1 2 3 4 5 6 7 8 9
Neutral
Reset
J1-
24VAC Interface
J1-
1 2 3 4 5 6 7 8 9
J2-
1 2
Relay
N.O.
COM
Dry Contact Closure
Description:
59 Minute Correction -
110VAC or 230VAC or 24VAC 60 Hz is used to run the clock normally. Applying
an eight (8) second reset signal from 57 minutes and 54 seconds will cause an hourly correction. Applying
a fourteen (14) second reset signal from 5:57:54 (am/pm) will cause twice a day correction.